Analog i/o, Figure 13 analog i/o dialog – Bird Technologies BDS-Manual User Manual

Page 42

Advertising
background image

28

Tolerance -

The Tolerance field defines the tracking filter window as a percentage from the center of the funda-

mental frequency. This gives the frequency range of a generator for a frequency.

Example - For a 2 MHz generator that moves from 1.8 to 2.2 MHz, you would enter a toler-

ance of at least 10%. The input value range for this field is 0.1 to 20%. The maximum toler-

ance for a frequency is limited based on the following formula: 5/frequency in MHz * 100.

Filter Width & Track Quality -

These are advanced parameters used to fine-tune the frequency tracking algorithm.

Note: It is recommended that these settings are kept at their default values of 0.1 and 0.01%, respectively.

Filter Width is used to widen or narrow the filters used to determine frequency lock.

Note: Filter Width ranges from 0.01 to 2.56%.
Note: Defaults for Filter Width: 0.1%.

Track Quality is used to adjust lock speed at the expense of accuracy. The higher the value, the lower the quality and
the lower the frequency accuracy.

Note: Track Quality ranges in value from 0.01 to 0.256%.
Note: Default for Track Quality: 0.01%.

Selected Frequencies -

Displays all frequencies that have been added to the measurement configuration. Fre-

quencies are listed in MHz. Column headers (from left to right):

Fundamental in MHz

Harmonic (overtone) number (0-15)

Intermod number (-3 to 3, 0 means no IMD)

Frequency in MHz.

Clicking on a fundamental in the list will highlight all frequencies for the fundamental.

Note: Harmonics or IMD frequencies can be clicked on individually.
Note: Clicking the “<< Remove” button will remove the highlighted frequencies from the list.

Analog I/O

The Analog I/O page provides options for configuring the DAC outputs and analog inputs.

Figure 13 Analog I/O Dialog

Advertising