Maintenance

17

Bird 4027A Series RF Power Sensors

CAUTION

Changing the sensor’s connectors will invalidate calibration data, and may

reduce the maximum power rating of the unit.

Frequency Range

4027A250K
4027A400K
4027A800K
4027A2M
4027A4M
4027A10M

250 – 400 kHz
400 – 550 kHz
800 – 950 kHz
1.5 – 2.5 MHz
3 – 5 MHz
10 – 15 MHz

4027A12M
4027A25M

10 – 15 MHz
25 – 30 MHz

RF Power Range

4027A12M
4027A25M

300 mW – 1 kW
3 W – 9 kW

All other models

3 W – 10 kW

Accuracy, Fwd, Best Case

*

* For rated accuracy, no more than 1% AM; Harmonics –50 dBc or less

Derate accuracy by 1% (1

σ

) outside cal. power or cal. frequency

Derate accuracy by 1% (1

σ

) below 15 °C and above 35 °C

± 1.0% (1

σ

)

Calibration Frequencies, Typical (MHz)

† Other calibration frequencies available upon request

4027A250K
4027A400K
4027A800K
4027A2M
4027A4M
4027A10M

0.25, 0.40
0.40
0.90
1.8, 2.0, 2.17
4.0, 5.0
10.0, 13.56, 15.0

4027A12M
4027A25M

10.0, 13.56, 15.0
25.76, 27.12, 28.48

Calibration Power, Typical

4027A12M
All other models

700 W
1.7 kW

VSWR, Max.

1.05:1

Insertion Loss, Max.

0.05 dB (with female “N” connectors)

Directivity, Min.

4027A12M
All other models

30 dB
28 dB