5

Item

(Fig. 2)

Function

Description

1

AC Power
Connector

Connect to ac power supply with a
power cord

2

Alarm
Interlocks

Alarm interlocks are used to shut down
transmitter when an alarm condition
occurs. Remote reset can be used to
reset the BPM-E after the alarm event

3

Analog
Output,
Forward
Power

0 to 2 V full scale, linear, 200 ohm
output impedance, BNC (f) connector

4

Analog
Output,
Reflected
Power

0 to 2 V full scale, linear, 200 ohm
output impedance, BNC (f) connector

5

Power/
Alarm Port

Connects to the BPM-E using a 15 pin
cable. Provides operating power to the
BPM-E. Contains analog and digital
alarm information.

6

RS-232
Serial Port

Connects to the BPM-E using a 9 pin
RS-232 cable (ASCII data between
the BPM-E and the display)

7

AC Power
Switch

Turns on the display panel (and BPM-
E if connected).

8

Mode
Button

Selects display mode for the right
field.

9

Units Button

Selects the displayed power units.

10

Alarm LED

Red LED, lights when an alarm is
triggered

11

Reset
Switch

Press to reset the alarm. If an alarm
trigger is still present, the alarm will
reactivate

12

Remote
Computer
Connector

Interface with a PC using a 9 pin RS-
232 cable

Advertising