Maintenance

Troubleshooting

For corrections requiring repair or replacement of compo-

nents, refer to the appropriate section for your specific

model.

Cleaning

Outside

Surface

The outside surface of these loads should be wiped free of

dust and dirt when necessary. The principle maintenance

required by the operator will be to periodically wipe the ac-

cumulated dust and lint off of the radiator fins. Excessive

collection of dust and lint on the cooling fins will interfere

with efficient dissipation of heat. If the Teflon insulator or

metallic contact surfaces of the connector should become

dirty or grimy, wipe them off with a soft cloth. Use a contact

cleaner that is self-drying and leaves no residue to clean the

hard to reach internal portions.

Inspection

With the rugged and simple construction of the loads, peri-

odic inspection will be necessary at only about six-month in-

tervals. Inspection should include the items listed below:

a. Cleanliness - Keep the housing and

connector free of grime.

11

PROBLEM

POSSIBLE CAUSE

REMEDY

Excessive over-
heating

Transmitter power
too high

Reduce transmitter
power.

Faulty RF resistor

Return to factory
for repair.

High or low dc re-
sistance values

Faulty RF input
“QC” connector

Replace.

Loose “QC” con-
nector

Tighten with
screwdriver.

Faulty RF resistor

Return to factory
for repair.

Table 1