Termaline Load Resistor 8745/8746

13

Figure 3 RF Input Assembly

Inspecting the Unit

Note:

Perform this once the resistor has been successfully removed.

1. Inspect the resistor carefully to ensure that it is not fractured.

Note:

In the majority of cases, even in the event of resistor failure,

the resistor substrate will remain intact.

2. Examine the inside of the load housing assembly for any apparent damage

to the internal parts.

3. Do one of the following:

z

If no damage had been found - Proceed with resistor replacement,

see “Replacing the Resistor” on page 14.

z

If the resistor is broken, other internal parts appear to be
damaged, or if they do not fit together properly
- See “Replacing
Fractured Resistors” on page 14.