Bird Technologies 4275 Series User Manual

Bird Technologies Accessories communication

Advertising
background image

921-4273/75S Rev B

Page 1 of 2

General

Models 4273 and 4275 are wide range adjustable Thruline® RF Couplers for signal observation on a scope or

frequency counter input. The output signal produced at the BNC output connector is an attenuated, unrectified

signal. They offer very low insertion VSWR across their frequency range and insertion loss is less than 0.2 dB.
The Model 4273 is a low frequency coupler for the 1.5 to 35 MHz band and offers a sample that ranges from 40

to 70 dB below the main power level. The Model 4275 covers a frequency band of 20 to 1000 MHz with an

attenuation range of 35 to 80 dB down from the main power. Both couplers have locking devices on their

attenuation control. Additional details on their performance characteristics are given under specifications.
Installation requires only that the coaxial cables have the mating connectors for the sampler. To obtain the

minimum insertion VSWR and loss, the N type connectors are preferred. Use an RF coaxial cable with a Male

BNC plug on one end to connect between the Female BNC port on the sampler and the scope or counter, All

versions on the models 4273 and 4275 are installed in an RF coaxial line through quick change “QC” connectors

except for the -100 models. These models are designed for direct mounting on any Bird device equipped with a

“QC” connector. Remove the “QC” connector from the device by unscrewing counterclockwise the four 8-32 x 5/

16 inch mounting screws. The -100 having no connectors of its own, is sandwiched between the “QC” connector

and the device. Place the “QC” connector on the female side of the sampler. Remount the “QC” connector and

sampler on the device by using the four 8-32 x 1-1/2 inch screws furnished with this sampler.
The operation of the variable samplers consists only of adjustment of the knurled coupling knob to obtain the

desired RF signal level a the BNC output port. The maximum output is obtained by screwing the knob

clockwise all the way in. The control shank threads have a special nonstrip provision when the knob is

screwed counterclockwise all the way out. To re-engage the threads, push the knob in gently and turn

clockwise. A locking lever is provided to prevent the chosen setting from being inadvertently disturbed.
Since the signal sampler is a passive device, it requires no external source of power or utility service.

Therefore, the unit cannot be turned off. The source of RF energy must be shut off instead.

These signal samplers are essentially very rugged and mechanically simple by design. They require very little

maintenance other than keeping them clean. Wipe the housing off occasionally with a clean dry cloth. In the

same way, wipe off the two “QC” connectors and the BNC port. Use a self-drying and nonresidue forming

aerosol contact cleaner on their inaccessible internal surfaces. Check the “QC” connectors from time to time to

be sure they are tightly and firmly mounted.
Other than replacing the “QC” connectors, there are no field repairs possible with the Models 4273 and 4275

Signal Samplers. Any other malfunction will require returning the sample to Bird Electronic Corp. for service.
To ship one of these samplers, screw the adjustment knob all the way in and lock it in place with the locking

lever. Wrap it carefully in padding and place it in a suitably sized corrugated paper box. Storage involves only

covering the device to keep off the dust and maintaining the ambient temperature between -40° and +45°C

(-40°F and +113°F).
There are no replacement parts for Models 4273 or 4275 except for the “QC” connectors. Listed below are

models equipped with suggested “QC” connectors.

CAUTION

Never attempt to disconnect the sampler from the transmission

line while RF power is being applied. Leaking RF energy is a

potential health hazard.

Instruction Sheet

Variable RF Sampler

Series 4273/75

Thruline® is a registered trademark of Bird Electronic Corporation

Advertising
This manual is related to the following products: