Mini autoquad, Tower top amplifier system, 434 mission critical series – Bird Technologies 434 Series User Manual

Page 2

Advertising
background image

Mini AutoQuad

TM

Tower Top Amplifier System

434 Mission Critical Series

MiniTowerTop_434missioncritical-04022014

30303 Aurora Rd.

Solon, OH 44139

866.695.4569

www.bird-technologies.com

SYSTEM SPECIFICATIONS

15 dB reserve gain and maximum 6 dB transmission line loss assumed

Frequency Band 700-800 MHz

Reserve Gain Configurable by electronic attenuator

Rejection 120dB nominal at 776 and 851 MHz

Total Power Dissipation 17W

System Noise Figure

3.2 dB Typ.

TOWER TOP AMPLIFIER SPECIFICATIONS

Frequency Band 792-824 MHz

Preselector Included Yes

Type of Amplifier Quadrature Coupled (Redundant)

TTA Gain (Input to output of TTA) +23 dB Typ.

Noise Figure: TTA 2.9 dB Typ.

LNA OIP3 > 42 dBm Typ.

Return Loss of all RF Ports > 14 dB

Power Requirements Power derived from Rx Cable

Operating Temperature Range -30° C to 60° C

Amplifier Redundancy Automatic change - over

Lightning Protection Impulse suppressor on all external ports

Test Port Included Yes

Coupling Test Port (Test in/Amp in) 30dB

50 Ohm Termination Test Controlled by base unit

Bypass Test Mode Controlled by base unit

Enclosure Weather resistant Housing,

Designed to NEMA Standards

Dimensions 8.65” x 5.77” x 6.04”

Net Weight 10 lbs

A steep skirted TEM bandpass filter in the tower box augmented by a ceramic filter in
the base unit provide a selective 32 MHz system window.

Model Numbers

Description

Power Req

434-83H-01-T

TTA, Mini AutoQuad, 792-824 MHz, Tower Box

434-83H-01-M-110

Multicoupler Unit (MCU), 16-port, 792-824 MHz

AC

434-83H-01-M-48

Multicoupler Unit (MCU), 16-port, 792-824 MHz

-48

434-83H-01-C-110

Control Monitoring Unit (CMU) for TTA, w/o RX Multicoupler, 792-824 MHz

AC

434-83H-01-C-48

Control Monitoring Unit (CMU) for TTA, w/o RX Multicoupler, 792-824 MHz

-48

BASE UNIT SPECIFICATIONS

MULTICOUPLER UNIT (MCU)
CONTROL MONITORING UNIT (CMU)

Frequency Band

MCU/CMU 792-824 MHz

Net Gain or Loss

(RMC in to Rx out)

MCU
CMU

+1 min.

-8 dB min.

Amplifier Type

MCU

Quadrature Coupled

Number of Output Ports

MCU
CMU

16 expandable to 32
1

RF Port Return Loss (Min)

MCU/CMU > 14 dB

TTA Connector

MCU/CMU N-Female

Receiver Connector

MCU
CMU

BNC-Female
N-Female

Rx-Rx Port Isolation (Min)

MCU/CMU >20 dB

Receive Test Port

MCU
CMU

N/A
1 N-Female

Test Port Input (Front of RMC)

MCU/CMU BNC- Female

Test Port Output (Rear of RMC)

MCU/CMU N- Female

Reserve Gain Electronic Attenuator

MCU/CMU 15 dB in 0.5 dB steps

Distribution Gain Electronic Attenuator

MCU/CMU 4 dB in 1 dB steps

Alarm Contacts

MCU

Form-C contacts

Power Requirements

MCU/CMU 90-240 VAC @ 50/60 Hz or -48 VDC

Operating Temp Range MCU/CMU 0°C to +50°C

Enclosure

MCU/CMU Standard EIA 19” Rack Mounting

Dimensions (HWD)

MCU/CMU 1 RU x 19” x 14” (38 x 483 x 356 mm)

Net Weight MCU

CMU

11.5 lbs
10.5 lbs

Tower Top Amplifier will function up to 70°C without shutting down however, the specifications are not
guaranteed outside the rated temperature range. CMU specifications values are typical unless noted otherwise.

OPTIONAL PRODUCTS

89-83F-03-03

792-806 MHz, 3 MHz Bandwidth Preselector

89-83F-03-06

792-806 MHz, 6 MHz Bandwidth Preselector

89-83F-03-09

792-806 MHz, 9 MHz Bandwidth Preselector

89-83F-03-14

792-806 MHz, 14 MHz Bandwidth Preselector

89-86A-03-03

806-824 MHz, 3 MHz Bandwidth Preselector

89-86A-03-05

806-824 MHz, 5 MHz Bandwidth Preselector

89-86A-03-10

806-824 MHz, 10 MHz Bandwidth Preselector

89-86A-03-15

806-824 MHz, 15 MHz Bandwidth Preselector

89-86A-03-18

806-824 MHz, 18 MHz Bandwidth Preselector

75-83K-01

Multicoupler Expansion Kit, 16-32 Port

75-83K-02

Multicoupler Expansion Kit, 16-40 Port

75-83K-03

Multicoupler Expansion Kit, 16-48 Port

91-00-123

TTA Mounting Bracket

MiniTowerTop_434_2012 branding 4/2/2014 10:04 AM Page 2