Bird Technologies 4421-488 User Manual

Bird Technologies Measuring instruments

Advertising
background image

MODEL 4421-488
PROGRAMMING CARD

General Bus Commands

FUNCTION

COMMAND

DESCRIPTION

Initialize

INT

Place in factory-set default conditions

Command
Trigger

TRG

Take a reading in T3 (one shot on trigger mode)

Software Hand-
shake

XO
XF

Enable software handshake
Disable software handshake

Enter Data

ENT

Send a reading to RS-232 controller

Baud Select

B1
B2

Set to 110
Set to 300

B3
B4
B5

Set to 600
Set to 1200
Set to 2400

B6
B7

Set to 4800
Set to 9600

Device Dependant Commands

FUNCTION

COMMAND

DESCRIPTION

Measurement

FC
FD

Forward Carrier Wave
Forward dBm

RC
RD

Reflected Carrier Wave
Reflected dBm

SW
RL

Standing Wave Ratio
Return Loss

MN
MX

Minimum Loss
Maximum Value

Range

RYY
R00

Auto range on
Lowest range

R01
.

.
.

R17
RNN

Highest range
Auto range off—stick on present range

Terminators

YT
YO
YN

Two terminators: CR, LF
One terminator: CR
No terminator

Prefixes

PY
PN

Prefix yes
Prefix no

Triggers

T0
T1

Continuous on ENT
One shot on ENT

T3
T5

One shot on TRG
One shot on measuerment command

Status

U0
U1
U2

Send back current machine state
Send back error conditions
Send back revision levels

Self-Test

J0

Run selt-test

Writable Store

WXXXXXX

Place XXXXXX in RAM

MODEL 4421-488
PROGRAMMING CARD

General Bus Commands

FUNCTION

COMMAND

DESCRIPTION

Initialize

INT

Place in factory-set default conditions

Command
Trigger

TRG

Take a reading in T3 (one shot on trigger mode)

Software Hand-
shake

XO
XF

Enable software handshake
Disable software handshake

Enter Data

ENT

Send a reading to RS-232 controller

Baud Select

B1
B2

Set to 110
Set to 300

B3
B4
B5

Set to 600
Set to 1200
Set to 2400

B6
B7

Set to 4800
Set to 9600

Device Dependent Commands

FUNCTION

COMMAND

DESCRIPTION

Measurement

FC
FD

Forward Carrier Wave
Forward dBm

RC
RD

Reflected Carrier Wave
Reflected dBm

SW
RL

Standing Wave Ratio
Return Loss

MN
MX

Minimum Loss
Maximum Value

Range

RYY
R00

Auto range on
Lowest range

R01
.

.
.

R17
RNN

Highest range
Auto range off—stick on present range

Terminators

YT
YO
YN

Two terminators: CR, LF
One terminator: CR
No terminator

Prefixes

PY
PN

Prefix yes
Prefix no

Triggers

T0
T1

Continuous on ENT
One shot on ENT

T3
T5

One shot on TRG
One shot on measuerment command

Status

U0
U1
U2

Send back current machine state
Send back error conditions
Send back revision levels

Self-Test

J0

Run selt-test

Writable Store

WXXXXXX

Place XXXXXX in RAM

Advertising