Bird Technologies 5000 Series User Manual

Page 40

Advertising
background image

Bird Model 5000 Digital Power Meter

26

Bird 5010 Sensor

Sensor Type /
Elements

*

Bird Thruline directional dual-
element line section. Uses two
Bird DPM Elements.

Power

0.1 to 1,000 W

Frequency Range

2 MHz to 3600 MHz

Accuracy

With DPM Elements:
±5% of reading 15 to 35 °C RSS
±7% of reading –10 to 50 °C RSS

Peak / Average

10 dB maximum with DPM
Elements.

Settling Time

< 2.5 seconds

Connectors

QC Type, Female N normally
supplied

Insertion VSWR

1.05:1 up to 1 GHz (with N
connectors).

Dimensions

2.5”H x 5.0”W x 2.0”D
(58 x 127 x 51 mm)

Weight

1.25 lb. (0.57 kg) nominal with
elements.

*

RFL element power must be 1/10 of FWD power.

Power and frequency range based on selected elements.