Introduction, Chapter 1 – Bird Technologies 6151A User Manual

Page 11

Advertising
background image

Chapter 1

Introduction

Purpose and

Function

The Bird Model 6151A Termaline RF Wattmeter is designed to measure RF power
under non-radiating conditions. The Wattmeter is coupled to an accurate 50 ohm
coaxial load resistor which becomes the transmitter load element, providing a
practically reflectionless coaxial line termination up to 2.3 GHz.

Power input to the load resistor is sampled by a coupler-detector type voltmeter
indicating directly in watts.

The Model 6151A is intended for general field and laboratory service use on CW,
AM and FM modulation envelopes, but not on pulsed modes.

Description

The Model 6151A Termaline Wattmeter consists of a coaxial load resistor, detector
circuit, dc cable, panel meter and its housing.

The load portion is comprised of an RF coaxial load resistor assembly encased in a
finned radiator. The detector circuit is in the Plug-in Element inserted in a short
length of 50 ohm coaxial line mounted on the front of the load portion. A 2-3/4 foot
(83.8 cm) coaxial cable (RG-58/U) connects the detector circuit to the meter which is
sealed and shock mounted in its housing.

The detector circuit in the Plug-in Element samples the RF energy travelling toward
the load, converts it to a small dc voltage for readout on the meter. The meter scale
is designed to indicate power directly in watts.

Specifications

Power Rating

100 W continuous

Power Ranges

25/50/100 Determined by plug-in
elements*

Input Impedance

50 ohms nominal

Frequency Range

2 to 2300 MHz Determined by plug-in
elements*

VSWR

1.1 to 1.0 max. dc to 1 GHz
1.25 to 1.0 max. 1 to 2.3 GHz

Accuracy

± 5% of full scale to 2.3 GHz

Input Connector

Bird quick change “QC” type Female N
normally supplied.

Dimensions

12-27/32" L x 3-15/16" W x 6-11/32"H
(326 x 100 x 161 mm)

Weight, Nominal

8 lb (3.6 kg)

Finish

Grey Powder Coat

*Refer to the Bird Electronic Corporation Catalog.
Any Element, up to 100 watts, may be selected from Tables I, II or III of the Cata-
log.

1