Chapter 3

Operating Instructions

Controls

The only operating control is the range selector switch on

the lower right hand face of the meter unit. No adjust-

ment or control settings are required.

Start-Up

Connect the load to the transmitting equipment under

test with 50 ohm coaxial cable (RG-8A/U, RG-9/U,

RG-213/U or equal) equipped with a Male N type plug

(UG-21E/U or equal) which mates with the RF input con-

nector of the load for Models 6732B, 6734B and

6734B-030. For Models 6735-300A, 6736A, 6736-030A,

6737A and 6737-030A use a cable equipped with a Male

LC type plug. After the transmitter has been connected to

the load, proceed according to the transmitter manufac-

turer’s instructions. When reconnecting the antenna, it

may be necessary to slightly adjust the transmitter due

to possible differences in VSWR between the load and the

antenna system.

Normal

Operation

Each Termaline Wattmeter will continuously measure

and safely dissipate RF power up to its maximum rating.

To operate, set the range selector switch to the desired

power range and turn on the RF power source. The RF

power absorbed by the load portion will be displayed on

the meter. Read the power level from the scale that

matches the range set by the range selector switch. For

Models 6737A and 6737-030A set the water rate to at

least ½ gallon/minute (2 liter/minute).

WARNING

When the unit is used in the upper range of its power

capacity, the radiator will become hot - care should be

used in touching the equipment.

WARNING

Do not attempt to operate the Termaline Wattmeter for

prolonged periods at higher than rated load levels.

Damage to the equipment and injury to operator may

result.