C. GAS CONNECTIONS

1. INSTALLATION INSTRUCTIONS

A.

SAFETYPRECAUTIONS

RETAIN THIS MANUAL FOR FUTURE REFERENCE.

B. UNPACKING INSTRUCTIONS:

FOR YOUR SAFETY, THE FOLLOWINGSAFETYPRECAUTIONSSHOULD BE FOLLOWEDAND ENFORCED.

IF YOU SMELLGAS:

·

SHUTOFF GAS SUPPLYTOAPPLIANCE

EXTINGUISHOPEN FLAMES

·

IMMEDIATELY CALLYOUR GAS SUPPLIER

Instructions must be posted in a prominent location. All safety precautions must be taken in the event the user smells

gas. Safety informationcan be obtained from your local gas supplier.

1. Aseparate gas shut-off valve must be installed in the gas line ahead of the unit, as required by

2. LIGHTING:Follow the instructionson page 4.

3. At least 24 inches must be provided at the front of for servicing.

4. When installing, never enclose the bottom area of the unit with a raised curb or other construction that

would obstruct the flow of air into the unit.

5. This unit may be operated with 0” (sides and back) minimum clearance to non-combustible construction

in areas that are non-combustiblelocations only.

6. This installation must conform to local codes, or in absence of local codes to the

, latest edition. In Canada it must conform to current

(natural gas) or

7. The appliance and its individual shut-off valve must be disconnected from the gas supply piping system

during any pressure testing of that system at test pressures in excess of ½ psi (3.45 kPa).

8. The appliance must be isolated from the gas supply piping system by closing its individual manual shut-

off valve during any pressure testing of the gas supply piping system at test pressures equal to or less

then ½ psi (3.45 kPa).

9. This appliance must be installed under a ventilationhood.

10. Do not obstruct the flow of combustionand ventilationair.

11. The area around this and any other gas appliance must always be kept free and clear from combustibles.

Carefully unpack the open burner range and inspect immediately for shipping damages. Your open burner

range was shipped in a carton designed to give maximum protection in normal handling. It was thoroughly inspected

before leaving the factory and the carrier accepted and signed for it. File any claims for shipping damage or

irregularitieswith the carrier.

codes.

National Fuel Gas Code

ANSI Z223.1/NFPA 54

Natural Gas Installation Code

CAN/CGA B 149.1

CAN/CGA B 149.2 Propane Installation Code for Gas Burning

Appliances& Equipment.

MAIN SHUT-OFF VALVE

PRESSURE REGULATOR

Figure “A”

STANDING PILOT

Advertising
This manual is related to the following products: