Save, Load – Blizzard Lighting Kontrol 6(Rev. A) User Manual

Page 14

Advertising
background image

KONTROL 6 Manual Rev B.

Page 14

© 2014 Blizzard Lighting, LLC.

ALL RIGHTS RESERVED

3.6 USB Functions

KONTROL 6 is capable of saving/loading scene and chase data from USB

drives, using the USB jack on the unit’s front panel. During USB operation,

KONTROL 6’s LED display will show the following information, depending on

mode.

LED Display

Means...

SAvE

Indicates KONTROL 6 is currently in Data Backup/Save Mode.

LoAd

Indicates KONTROL 6 is currently in Data Load Mode.

UP--

Indicates KONTROL 6 is currently in Firmware Update Mode.

Ft01-Ft16

Displays the current file number to be written/loaded

ot

“OK,” indicates that the current file operation was successful.

FAIL

Indicates that the current file operation was unsuccessful. Try a different USB

device or program.

3.6.1 Data Backup

Allows the user to save scene and chase data to a USB Flash “Thumbdrive.”

1. Press and hold the <RUN MODE> & <LEFT> buttons to enter Data

Backup Mode.

2. KONTROL 6’s LED display will show “

SAvE

.”

3. Use the <FIXTURE SELECTOR 1-16> buttons to select the file

name, “FILE1 - FILE16.”

4. Once backup is complete, KONTROL 6 will display the “OK” message

(

ot

) as indicated above

3.6.2 Data Load

Allows the user to load scene and chase data from a USB Flash “Thumb-

drive.”

1. Press and hold the <RUN MODE> & <RIGHT> buttons to Enter

Data Load Mode.

2. KONTROL 6’s LED display will show “

LoAd

.”

3. Use the <FIXTURE SELECTOR 1-16> buttons to select the file

name, “FILE1 - FILE16.”

4. Once data load is complete, KONTROL 6 will display the “OK” mes-

sage (

ot

) as indicated above

3.6.3 Firmware Update

Allows the user to upgrade KONTROL 6’s internal firmware from a USB Flash

“Thumbdrive.”

Advertising