Bunn CRTF5 User Manual

Page 21

Advertising
background image

Page 21

SERVICE (cont.)

TANK HEATER (Cont.)

P1168.71

FIG. 13 TANK HEATER TERMINALS

10478 061500

13. Secure sprayhead tube to hood using a hex nut.
14. Install sprayhead.
15. Reconnect the wires to the limit thermostat, tank

heater and control thermostat. See limit thermo-
stat and control thermostat sections in this manual
when reconnecting wires.

16. Install fill basin, secure with tank inlet fitting and

gasket. Insert water supply line through grommet
in fill basin.

17. Refer to Fig.13 when reconnecting the tank heater

wires.

WHI to Terminal Block
(White Insert on 230V
Two Wire Models)
RED to Terminal Block
(Red Insert on 120/240V
Three Wire Models or
200V and 240V Two
Wire Models

BLK to Control Ther-
mostat (Brewers W/Out
Faucet)
Thermal Cut-Off to BLK
from Control Thermo-
stat (Brewers W/Fau-
cet)

Advertising