DIGITAL PRO MIXER DDM4000 User Manual

Automatically detecting beats with AUTO BPM:
The BPM Counter detects the tempo of the signal source assigned to

the Effect section. The signal source is shown in the BPM section of the

display. (Assigning the signal source to the BPM/Effect section is described

in Chapter 4.1.1.)
1) Make sure that “Auto BPM” is activated. When active, the AUTO BPM

push button (50) shines yellow and the BPM indicator flashes on the display.

Should Tap Mode be active (AUTO BPM push button shines blue),
press the AUTO BPM push button longer than one second to
activate Auto BPM.

2) Now the BPM Counter determines the BPM value of the played signal.

It is constantly brought up to date to be able to respond immediately to

any tempo changes.

Manually detecting beats with TAP:
1) Make sure that Tap Mode is activated. When active, the AUTO BPM/TAP

push button (50) shines blue and the BPM indicator shows “Manual.”

2) Tap the TAP push button (50) (at least 2x) in the rhythm of the music,

which results in a constant BPM value. Here’s a tip: while tapping,

listen in on the signal using the headphones.

Should Auto BPM be active (AUTO BPM push button
shines yellow), go to Step 2. When tapping the tempo, Manual Mode
is automatically activated.

3) The BPM value can always be readjusted by tapping over and over again.

The Auto BPM is always active when the device is turned on.

Without a music signal (or one which is too quiet), the BPM value
flashes on the display. In addition, the message “Low Level” appears on
the display. The BPM value also flashes when the beat cannot be clearly
identified (message “Uncertain”).

4.3 MIDI clock

The MIDI Clock is used as a time reference for the Bounce function. In addition,

the MIDI Clock is given out at the MIDI output. This allows you to synchronize

external devices, which are able to receive MIDI Clock (such as drum machines

and grooveboxes) with the DDM4000.

(53)

(52)

(51)

Fig. 4.7: BPM section

Press the push button (52) to start and stop the MIDI Clock.

You can adjust the tempo of the MIDI Clock. Alternatively, the MIDI Clock can also

be synchronized with one of the two BPM Counters:

MIDI BPM:
When in MIDI BPM Mode, “MIDI BPM” appears in the middle of the display

below the BPM indicator of the MIDI Clock. Adjust the tempo by turning the

CONSOLE SETUP knob (51). It is possible to make bigger value jumps by pressing

and simultaneously turning the knob.

FX 1/FX 2 BPM:
To transmit the detected tempo of the BPM Counter to the MIDI Clock,

press one of the ADJUST push buttons (53). By pressing the left BEAT push button,

the MIDI Clock adopts the tempo of the left BPM Counter. By pressing the right

BEAT push button, the MIDI Clock adopts the tempo of the right BPM Counter.

The assignment is indicated by displaying “FX 1 BPM” or “FX 2 BPM.”
Cancel the assignment by turning the CONSOLE SETUP knob to specify

your own tempo.
The tempo of the MIDI BPM can also be transmitted to the BPM Counter. Hold the

left or right ADJUST push button (53) (or both at the same time) while selecting

the tempo with the CONSOLE SETUP knob (51). This function is useful when

assigning effects to a channel which is configured as MIDI controller so that the

Auto BPM function does not work.

5. Sampler

(54)

(60)

(61)

(64)

(66)

(65)

(63)

(62)

(59)

(58)

(57)

(56)

(55)

Fig. 5.1: Sampler section

A sampler is a device used to record and play back audio signals.

The DDM4000’s sampler lets you record two tracks which then can be

played back. These tracks are single short sequences, vocal phrases, rhythmic

loops or even longer song passages. Any audio signal fed to the mixer can be

used as signal source, usually found on the stereo channels, the Microphone

channel and the stereo sum. The maximum recording duration is 32 seconds.

The samples can be played back in various ways (as infinite loop/loop, one time,

forward, reverse).