TROUBLESHOOTING

• If the laser remains lit, or the value in the Main Display keeps changing,

flashing, or showing “trc” you are in Continuous Measure mode. Press On/
Measure

(Key 1) once to exit this mode.

• If the message Error does not disappear after switching on and off the device

repeatedly, contact Calculated Industries.

• If the message InFo appears with a number, follow the instructions in the fol-

lowing table.

No.

Cause

Remedy

204

Calculation error

Measure again.

252

Temperature too high

Let the device cool down.

253

Temperature too low

Warm the device up.

255

Reception signal too weak,

Change target surface (e.g., white paper).

measuring time too long

256

Input signal too high

Change target surface (e.g., white paper)

257

Measuring error,

Shadow the target area.

too much background light

258

Measurement outside

Target is beyond range.

of the measuring range

Move closer to target.

260

Laser beam interrupted

Repeat the measurement.

SPECIFICATIONS

Measuring Range

4” (10 cm) to 100’ (30.5 m)

Accuracy

+/- 1/8” (3 mm) or better over entire range

Smallest unit displayed

1/16 (1 mm)

Laser class

2

Laser type

635 nm, < 1 mW

Automatic shut-off

After 3 minutes

Continuous measuring

Yes

Addition/Subtraction

Yes

Area

Yes

Volume

Yes

Pythagoras (Indirect)

Yes

Metric and Imperial Units

Yes

Dimensions

4.75 x 2 x 1” (118 x 50 x 26 mm)

Battery life

Up to 3,000 measurements

Weight

3.22 ounces (100g)

Temperature range:
- Storage

-13°F to +158°F (-25°C to +70°C)

- Operation

32°F to +104°F (0°C to +40°C)