Replacing r4300 modules, Replacing the r4300 fan pack, Figure 57 – ClearCube R Series Pentium 4 User Manual

Page 116: Fan pack attachment points

Advertising
background image

106 • Hardware Upgrade and Replacement Procedures

ClearCube Product Manual and Installation Guide

Replacing R4300 Modules

R4300 modules are hot-swappable. To replace a module, do the following:

1. Label all cables attached to the module.
2. Remove the cables.
3. Press down on the two green levers on each side of the module.

NOTE: Management modules have only one lever.

4. Pull the module from its bay. The old module must remain out of the bay for at

least five seconds for the replacement module to be recognized by the system.

5. Place the replacement module squarely in the bay, slide it in, and press firmly to

seat it.

6. Replace the cables.

Replacing the R4300 Fan Pack

To replace the Fan Pack on the R4300 BackPack, do the following:

1. Using a #2 Phillips screwdriver, remove the 5 screws on the back of the Cage that

attach the fan pack.

2. Insert a finger in the slot on the left side of the fan pack and slowly pull the fan

pack out. If you are hot-swapping the fan pack, wait for the fans to stop spinning

before setting it aside.

3. Slowly insert the new fan pack to ensure proper seating of the connector.
4. Replace the screws to secure the fan pack.

Figure 57 Fan Pack Attachment Points

R4300

BSBP

(DCBP similar)

Advertising