Electro-magnetic interference (emi) immunity, Power harmonics and flicker, Safety compliance – ClearCube R Series Pentium 4 User Manual

Page 128

Advertising
background image

118 • Appendix B – Regulatory Compliance

ClearCube Product Manual and Installation Guide

Electro-Magnetic Interference (EMI) Immunity

This equipment was also tested in accordance with the procedures given in the EN

55024: 1998 – Information Technology Equipment, Immunity Characteristics – Limits

and methods of measurements and was found to comply with:

EN 61000-4-2: 1995, Electrostatic Discharge Immunity Test, performance criteria:

4/8 kV

EN 61000-4-3: 1995, Immunity to Radiated, Radio Frequency, Electromagnetic

Fields, performance criteria: 3 V/m

EN 61000-4-4: 1995, Electrical Fast Transient/Burst Requirements, performance

criteria: 1 kV/.5 kV

EN 61000-4-5: 1995, Surge Immunity Requirements, performance criteria: 2/1 kV

EN 61000-4-6: 1996, Conducted Disturbance Induced by Radio-Frequency Fields

Immunity, performance criteria: 3 Vrms

EN 61000-4-8: 1994, Power Frequency Magnetic Field Immunity, performance

criteria: 1 A/m

EN 61000-4-11: 1994, Voltage Dips, Short Interruptions and Voltage Variations

Immunity, performance criteria: 95%-5c and 250c, 30%-25s

Power Harmonics and Flicker

Other requirements that this equipment has been found to comply with are:

EN 61000-3-2: 1995, Limits for Harmonic Current Emissions (equipment input

less than or equal to 16 A per phase)

EN 61000-3-3: 1995, Limitation of Voltage Fluctuations and Flicker in Low Voltage

Supply Systems for Equipment with rated Current = 16 A

Safety Compliance

The C3-R Cage, R1200 Blade, R2100 Blade, C/Port and MVX was tested and is

certified to the following safety standards:

UL 60950 3

rd

Ed., 7-28-95 with revisions through and including 3-1-98, TUV

Rheinland of N.A. (an OSHA accredited Nationally Recognized Test Laboratory)

Certificate CU72040336.

CAN/CSA-C22.2 No. 60950-00, TUV Rheinland of N.A. Certificate CU72040336

IEC 60950:1999, CB certificate US-TUVR-2088

Country Deviations from CB Bulletin 107a considered under the scope of the above certificate are, but

may not be limited to; Argentina, Austria, Australia, Belgium, Brazil, Canada, Switzerland, China,

Czech Republic, Germany, Denmark, Spain, Finland, France, United Kingdom, Hungary, Ireland,

Israel, India, Italy, Japan, Korea, Malaysia, Netherlands, Norway, Poland, Portugal, Russia, Sweden,

Slovenia, Slovakia, Singapore, Turkey, Ukraine, United States, and South Africa.

Advertising
This manual is related to the following products: