Blade switching and direct connect backpacks, Figure 27, R4300 daisy-chain cabling example – ClearCube R Series Pentium 4 User Manual

Page 70

Advertising
background image

60 • Cage and Blade Installation

ClearCube Product Manual and Installation Guide

NOTE: Connecting a network cable to a C/Port jack on the Cage, or a C/Port cable to

a Network jack, will not damage the unit, but the system will not operate

correctly. This is a common installation error and should be one of the first

things checked when troubleshooting a problem with a system’s operation.

Blade Switching and Direct Connect BackPacks

To connect cables to a Blade Switching BackPack-equipped Cage, do the following:

1. Label, identify, or use different color cables to discriminate between desktop and

network wiring. For example, use grey for the network cables and blue for the

ClearCube desktop cables.

2. Connect eight C/Port cables from the Cage ports marked C/PORT to the patch

panel going to your desktops. Skip this step if installing I/Ports.

3. Connect eight network cables from the Cage ports marked ETHERNET to your

Ethernet network hub or switch.

4. Connect the CONTROL IN port on the primary Cage (the Cage with the primary

RMC) to your network switch. Daisy-chain the CONTROL OUT port on the

primary Cage to the next Cage’s CONTROL IN port using the green daisy-chain

cable. Continue this daisy chain to connect all Cages in the rack.

Figure 27 R4300 Daisy-Chain Cabling Example

Admin C/Port

CLEARCUBE

Spare

Primary Cage

To Network

Secondary Cage

Tertiary Cage

with E-net Control Link

Admin

Daisy Chain

Control

Chain

Configuration

Cable

To Network

with E-net Control Link

No E-net Control Link

Spare

Daisy Chain

Admin

Daisy Chain

Admin C/Port

and Terminal