Multiple story mdus/exterior installation – CommScope Drop Cable User Manual

Page 52

Advertising
background image

Multiple Story MDUs/Exterior Installation

It may be simpler to run the cable on the outside of the building up to each floor or each apartment. A separate

cable will be needed for every unit. As always, make a thorough visual inspection of the proposed route and all

outlet locations.

Prior to installing the cable, read page 9.4 for the methods needed to locate and drill your entry hole.

Running Cable to Each Unit

Use a ladder of greater height than required or a bucket truck to run the cable up the side of the building. Look

for vertical and horizontal architectural elements that will help disguise the installation. Be sure you are using an

outdoor-rated cable.

Take the cable end with you up to the entry point.

Form more cable that you will need (you can never

use too much) into a loose loop. Tie off the loop with

a cable tie and attach the cable to the building wall

with a cable clip. Don’t let the loop hang free until

you have at least two clips in the wall.

Continue to attach the cable to the wall using clips

every 3 feet (1 meter) until you reach the point where

you want to turn downward. Being careful not to ex-

ceed the bend radius, attach the cable to the wall as

you descend.

Return to the entry point and enter the wall as de-

scribed on page 9.4. Untie the cable loop and feed

the cable through the hole.

10.5 Multiple Dwelling Units (MDUs)

Taller Buildings Outside

Advertising