Communication tool exportable results: edge tool, Communication tool exportable results: object tool – Banner PresencePLUS P4 GEO 1.3 Series User Manual

Page 127

Advertising
background image

Communication Tool Exportable Results: Edge Tool

Description

Value

Data Label

User-defined name

string

Tool Name

Tool processing time for the current inspection.

ms

Execution Time

Fastest recorded tool processing time since the start of the
inspection or since power-up.

ms

Execution Time Min

Slowest recorded tool processing time since the start of the
inspection or since power-up.

ms

Execution Time Max

Total number of bright-to-dark edges.

whole number

Bright-to-Dark Count

Total number of dark-to-bright edges.

whole number

Dark-to-Bright Count

Total number of all edges.

whole number

Total Edge Count

X, Y coordinates of all the edges found.

pixels (X, Y)

Location(s)

Communication Tool Exportable Results: Geometric Count Tool

Description

Value

Data Label

User-defined name

string

Tool Name

1 = Tool executed successfully

0 = Tool did not find a point to use as a reference

1 or 0

Success

Tool processing time for the current inspection.

ms

Execution Time

Fastest recorded tool processing time since the start of the inspection
or since power-up.

ms

Execution Time Min

Slowest recorded tool processing time since the start of the inspection
or since power-up.

ms

Execution Time Max

Total number of patterns above the minimum acceptance leval and
below the maximum number of patterns.

whole number

Match Count

X, Y coordinates of the point from ROIs will rotate.

pixels (X, Y)

Rotation Origin

Rotational value of the first pattern found.

degrees

Match Rotation

X, Y coordinates of the first pattern found.

pixels (X, Y)

Best Match Location
Point

Percent match of the first patttern found.

20-100%

Best Match %

Communication Tool Exportable Results: Object Tool

Description

Value

Data Label

User-defined name

string

Tool Name

Tool processing time for the current inspection.

ms

Execution Time

Fastest recorded tool processing time since the start
of the inspection or since power-up.

ms

Execution Time Min

127

Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com

Tel: 763.544.3164

P/N 000000

PresencePLUS Software Tools

7/2009

Advertising