Q85 series ac/dc sensors, Dimensions, q85 series sensors, Timing logic selection and hookup – Banner Q85 Series User Manual

Page 3

Advertising
background image

3

Top view

Dimensions, Q85 Series sensors*

Bottom view

*Emitter units have same dimensions but no SENSITIVITY control, logic

timing adjustments, or indicator LEDs.

The output timing logic function (on sensor models with T9 model

number suffix) is selected at the timing logic programming switches,

according to the table (below). The output timing logic delays are

set at the single-turn time adjustment potentiometer. When the tim-

ing function involves more than one time (as in ON and OFF delay,

ON-delayed one-shot, and ON-delayed limit timer functions), the

potentiometer sets both times to the same value.

Logic function

Switch: SW1

SW2

SW3

ON and OFF delays (both)

0

0

0

ON delay (only)

0

0

1

OFF delay (only)

0

1

0

No delays

0

1

1

ON delayed one-shot

1

0

0

ON delayed limit timer

1

0

1

One-shot

1

1

0

Limit timer

1

1

1

Timing Logic Selection and Hookup

Light/dark Operate switch

detail (basic on/off models):

0

1

L.O.

D.O.

SW1

SW2

SW3

Timing Logic Programming

switch detail (T9 models),

see table (left):

With the light/dark operate switch (all models) set to light operate

(L.O.), the sensor's output is energized when the sensor sees its own

modulated light source. In the dark operate (D.O.) position, the

output is energized when the sensor does not see its modulated light

source. Sensor sensitivity is set at the single-turn sensitivity adjust-

ment potentiometer.

Shown with SMB85B mounting bracket

(included with sensor)

Shown with SMB85R mounting bracket

(p/n 32798, order separately)

Q85 Series ac/dc Sensors