R58 expert, Registration mark sensors, Dynamic teach – Banner R58 Registration Mark Sensors User Manual

Page 5: Maximum feed rate, Dynamic teach and manual adjust, Teach sensing conditions, Return to run mode

Advertising
background image

P/N 122928 rev. C

5

Banner Engineering Corp. • Minneapolis, MN U.S.A

www.bannerengineering.com • Tel: 763.544.3164

R58

Expert

Registration Mark Sensors

Dynamic TEACH

Dynamic TEACH is used to configure sensitivity during actual sensing conditions, when
looking for a mark against its background condition. The R58E takes multiple samples of the
registration mark against its background material and automatically positions the threshold at the
optimum level. See Figure 2. The registration mark must be presented at least two times during
Dynamic TEACH.

When Dynamic TEACH is used, the Output ON state will be the shorter duration (smaller)
event sensed, and LO/DO will be set accordingly. To change the output state, change to either
LO or DO in SETUP mode, or pulse the remote line three times (see page 8).

Maximum Feed Rate

In order to optimize performance and ensure that all LED color and gain combinations
are evaluated during Dynamic TEACH, the registration mark must encompass the 1.2 mm
dimension of the 1.2 mm x 3.8 mm sensing image for at least 0.002 seconds. Therefore, the
maximum feed rate can be determined with the following formula:

Maximum Feed Rate in mm/sec. = (registration mark width in mm – 1.2) / 0.002

Example with a 5 mm registration mark:

Maximum Feed Rate = (5 mm – 1.2) / 0.002 = 1900 mm/sec.

NOTE: Registration marks narrower than the 1.2 mm sensing image width can be detected at

feed rates less than 600 mm/sec, but the contrast will be reduced, due to averaging of
the background and the registration mark.

Dynamic TEACH and Manual Adjust

Sensitivity may be adjusted at any time when the sensor is in RUN mode by clicking the “+”
and “-” buttons. Each click translates to 1/2 segment on the bargraph display. For best sensing
reliability, the light and dark conditions should register equally distant from the switchpoint on
the bargraph display.

Procedure

Result

Push Button

Remote Line

Access

TEACH

Mode

• Press and hold the

Dynamic push button
for > 2 seconds.

• Hold the remote line low

for > 2 seconds.

LO and DO: Alternately flash Green
Output: OFF
Bargraph display: Goes OFF

Teach

Sensing

Conditions

• Continue to hold Dynamic

push button.

• Present sensing conditions

(present registration mark
at least twice).

• Continue to hold the remote

line low.

• Present sensing conditions

(present registration mark
at least twice).

LO and DO: Alternately flash Green
Output: OFF
Bargraph display: Remains OFF

Return

to

RUN

Mode

• Release the Dynamic

push button.

• Release remote line/switch.

Teach Accepted

• Bargraph display flashes one segment for three seconds to indicate

relative contrast (see contrast table above).

• Sensor enters RUN mode.

Teach Unacceptable

• Pairs of bargraph display segments flash in unison for three seconds to

warn of unacceptably low contrast.

• Sensor returns to RUN mode without changing settings.

T

T T T

T

T

0.8 seconds

> 2 seconds

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T T T

T

T

0.8 seconds

> 2 seconds

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T T T

T

T

0.8 seconds

> 2 seconds

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

Bargraph

Display

Segment*

Relative Contrast /

Recommendation

6 to 8

Excellent: Very stable operation.

4 to 5

Good: Minor sensing variables

will not affect sensing reliability.

2 to 3

Low: Minor sensing variables

may affect sensing reliability.

1

Poor: Consider an alternate

sensing scheme.

*Following TEACH

NOTE: High contrast relates directly to sensing
reliability; high-contrast sensing applications are
most tolerant of sensing variables (e.g., web flutter or
variations in registration mark color and print density).

Sensor positions

threshold midway

between taught conditions

Sensor positions

threshold midway

between taught conditions

Darkest

(no signal)

Most Light

(saturated

signal)

Single
taught

point

Sensing window size

adjusted by

Manual Adjust

Output OFF

Output OFF

Output OFF

Output ON

Output ON

Condition of

Longer Duration

Condition of

Shorter Duration

Position

adjusted by

Manual Adjust

Output OFF

Output ON

2nd Taught

Condition

1st Taught

Condition

Position

adjusted by

Manual Adjust

Figure 3. Dynamic TEACH (Light or Dark

Operate, depending on the sensing

condition shown)

Advertising