Installation 5 – Breckwell P2700 User Manual

Page 5

Advertising
background image

SPECIFICATIONS


Width: 23 1/8”
Height: 30 ½”
Depth: 22 ¼”
Weight: 233 lbs.
Flue size: 3” or 4”
Hopper Capacity: Up to 50 lbs.
(This can vary widely depending on pellet
size, length, and diameter)
EPA status: exempt
Burn time: 1 lb. to 5.5 lbs. per hour
BTU range: 8,200 to 50,000
Approved installations: mobile home,
alcove, conventional

PREPARATION


Factory packaging must be removed, and
some minor assembly work is required
prior to installation. Access to the rear of
the stove is necessary.

NOTE: Normally, your dealer will perform
these functions.

CLEARANCES


The Breckwell P2700 Freestanding has
been tested and listed for installation in
residential, mobile home and alcove
applications.

FLOOR PROTECTION: Freestanding
installations, minimum 24” wide by 29”
deep. The stove must be placed on a
continuous (grouted joints)
noncombustible material such as ceramic
tile, cement board, brick, 3/8” millboard or
equivalent, or other approved or listed
material suited for floor protection. NOTE:
ceramic tile, or any tile, requires a
continuous s heet beneath to prevent the
possibility of embers falling through to the
combustible floor if cracks or separation
should occur in the finished surface, this
would include floor protection for Built-in
raised hearths. Check local codes for
approved alternatives.

Clearances are measured from the sides,
back and face (door opening) or stove
body (refer to fig. 3).

DO NOT USE MAKESHIFT MATERIALS
OR COMPROMISES IN THE
INSTALLATION OF THIS UNIT.

INSTALL VENT WITH CLEARANCES
SPECIFIED BY THE VENT
MANUFACTURER.

INSTALLATION

5

FIGURE 1

FIGURE 2

FLOOR PROTECTION

(MINIMUM 24” W X 29” D)

FIGURE 3