Watts P3 User Manual

Watts p3, Multi-orifice flow control for tankless heaters, Capacity

Advertising
background image

Watts P3

Multi-Orifice Flow Control

for Tankless Heaters

Adjusts to 3, 3

1

2

or 4 gpm

Watts No. P3 Flow Control valve is designed to limit the flow of water
to equipment and is used for tankless heater installations. It features a
multi-orifice design which lets you select a flow of 3, 3

1

2

or 4 gpm,

simply and quickly, by turning the cap to the desired setting. If a dif-
ferent setting is desired, simply move the adjusting cap to the desired
setting, locating this over the matching line on the body.

Capacity

Watts No. P3 Flow Control is designed to give the rated capacity in
gallons per minute as numbered on the adjustment cap at 50 psig
supply pressure. For other pressures, refer to the Flow Table for corre-
sponding adjustment setting. It is recommended that supply pressure
be determined with a gauge to assure accurate flow. For example, 80
psi supply pressure results in the following:

Adjustment Setting No.

Flow gpm @ 80 psi

3

3.8

3

1

2

4.4

4

5.1

Installation

Multi-Orifice cylinder
adjusts to
3, 3

1

2

or 4 gpm.

WATTS

No. P3

No. Andover, MA

2

1

2

3 3

1

2

4

gpm

@

50 psi

*Adjustment Cap Settings

Dimensions

ES-P3

Hot Water

Boiler

Hot to

Appliances

Tempered

Watts 1170

Tempering

Valve

Cold

Watts 3L
Pressure

Relief

Watts P3

Tankless Heater

Dimensions

Model

Size

A

B

C

Weight

P3

1

2

"

1

5

8

"

1

2

"

2"

6 ozs.

A

B

C

Vertical marker line just to left of 3 gpm marker line signi-
fies minimum adjustable volume (approx. 2

1

2

gpm) when

supply pressures exceed 50 psi.

Flow Table (gpm)

Adjustment

Supply

Setting No.

Pressure psi

3

3

1

2

4

30

2.3

2.7

3.1

40

2.7

3.1

3.6

*50

3

3.5

4

60

3.3

3.8

4.4

70

3.5

4.1

4.7

80

3.8

4.4

5.1

90

4

4.7

5.3

100

4.2

4.9

5.6

110

4.5

5.2

5.9

120

4.6

5.4

6.2

130

4.8

5.6

6.4

140

5

5.8

6.7

150

5.2

6.1

6.9

Hot

Watts No. 174A

Job Name

Contractor

Job Location

Approval

Engineer

Contractor’s P.O. No.

Approval

Representative

USA: 815 Chestnut St., No. Andover, MA 01845-6098; www.wattsreg.com

Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscda.com

Advertising