Watts LFN388 User Manual

Series lfn388, Lead free, Hot or cold water anti-siphon vacuum breaker

Advertising
background image

Series LFN388

Hot or Cold Water Anti-Siphon

Vacuum Breaker

Sizes:

1

4

" and

3

8

" (8 and10mm)

Bottom Inlet and Outlet Connections

Series LFN388 represents a line of vacuum breakers de-

signed to prevent backsiphonage of contaminated water into

the potable water supply. The LFN388 features Lead Free*

construction to comply with Lead Free* installation require-

ments.
They feature a lightweight, durable “disc float" suitable for

temperatures up to 180°F (82°C) which closes the atmo-

spheric vent to prevent spilling under all rates of flow. They

are ideally recommended for low flow installations such as

laboratory equipment which use small amounts of water.

They also contain a durable silicone disc which has high heat

and water hammer shock resistance and assures tight seat-

ing with the lightest of seating contact.
Full Size Orifice - All Series LFN388 valves have a full-size ori-

fice to assure pipe size capacity. Water passages are stream-

line to provide high water flow with minimal pressure loss.

Features

• Lead Free* cast copper silicon alloy body
• Full size orifice for maximum flow
• Lightweight disc assembly prevents spilling under all rates

of flow

Models

N388

Lead Free* cast copper silicon alloy body

N388-SC Satin Chrome
N388-C

Polished Chrome

Applications

• Bottle Washers
• Chemical Dispenser
• Dishwasher
• Photographic Tanks
• Shampoo Sinks
• Soap Dispensers

For Health Hazard Applications

ES-LFN388

Job Name –––––––––––––––––––––––––––––––––––––––––––

Contractor ––––––––––––––––––––––––––––––––––––––––––––

Job Location –––––––––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Engineer –––––––––––––––––––––––––––––––––––––––––––––

Contractor’s P.O. No. ––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Representative ––––––––––––––––––––––––––––––––––––––––

LFN388

Specifications

For Anti-Siphon Vacuum Breakers
An atmospheric type anti-siphon vacuum breaker shall be

installed where indicated on the plans to prevent the back-

siphonage of contaminated water. The device shall include

lightweight disc float with silicone disc for tight seating. This

device is not to be used under continuous pressure or where

there is a possibility that a backpressure condition may de-

velop. The vacuum breaker shall be constructed using Lead

Free* cast copper silicon alloy materials. Lead Free* vacuum

breakers shall comply with state codes and standards, where

applicable, requiring reduced lead content. The device shall

meet the requirement of ASSE Standard 1001: CSA B64.1.1.

Watts Series LFN388.

Vacuum Breakers are not designed, tested or approved to protect

against backpressure backflow. For protection against backpressure

backflow, install Watts No. 909/009 Series Reduced Pressure Principle

Backflow Preventers.

LEAD FREE

*

* The wetted surface of this product contacted by consumable water

contains less than 0.25% of lead by weight.

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,
please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with-
out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

NOTICE

Advertising