Watts OFTWH-RES User Manual

Model oftwh-res, Lead free, Oneflow

Advertising
background image

For Residential Applications

ES-OFTWH-RES

Job Name –––––––––––––––––––––––––––––––––––––––––––

Contractor ––––––––––––––––––––––––––––––––––––––––––––

Job Location –––––––––––––––––––––––––––––––––––––––––

Approval ––––––––––––––––––––––––––––––––––––––––––––––

Engineer –––––––––––––––––––––––––––––––––––––––––––––

Contractor’s P.O. No. ––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Representative ––––––––––––––––––––––––––––––––––––––––

Connection Sizes:

3

4

" (20mm)

Flow Rates: From 0.5 gpm to 6 gpm (1.9 lpm to 38 lpm)
The OneFlow

®

Anti-Scale System provides protection from

scale formation on internal and external plumbing surfaces.

The OneFlow

®

system is a single cartridge-based system

that must be installed on a cold water line prior to a single

water heating device (water heater or tankless water heater).
OneFlow

®

uses template assisted crystallization (T.A.C.) to

attract hardness minerals and convert them into harmless,

inactive microscopic crystal particles.
These crystals stay suspended in the water and are passed

to drain. The system requires very little maintenance, no back-

washing, no salt and no electricity. Typical hardness problems,

especially build-up of scale in heating elements, pipes, water

heaters, boilers and on fixtures are no longer a concern.
OneFlow

®

is not a water softener. It does not add chemicals. It

is a scale prevention device with proven third party laboratory

test data and years of successful commercial, residential and

foodservice applications. OneFlow

®

is the intelligent scale solu-

tion and is a great alternative to water softening (ion exchange)

or scale sequestering devices.

Features

• Chemical-free scale prevention and protection - converts hard-

ness minerals to harmless, inactive microscopic crystals mak-

ing OneFlow

®

an effective alternative to ion exchange water

softeners

• Virtually maintenance free - No salt bags or other chemicals

to constantly add or maintain

• No control valve, no electricity and no wastewater
• Uses environmentally friendly “green” technology
• Improves efficiency of all water heating devices and

downstream plumbing components

• Simple sizing & installation – standard

3

/

4

" connections

• Perfect system for homes where equipment protection

is desired for longer equipment life and reduced energy

consumption

• Inlet ball valve for easy isolation shutoff and filter changes
• OneFlow

®

cartridge-based systems are easily maintained;

change the cartridge once every two years

• Easily installed mounting bracket included w/filter wrench

to allow cartridge change-outs when necessary

Model OFTWH-RES

OneFlow

®

Anti-Scale System

Models

Model

Peak Flow Rate

Connection Size

OFTWH-RES

6 gpm (38 lpm)

3

4

" (20mm) FNPT

Replacement Cartridge

OFTWHRM-RES Cartridge should be replaced every 2 YEARS.

Specifications

A OneFlow

®

scale prevention system shall be installed on the

cold water service line to condition the tap water just prior to

the service line feeding the equipment it is designed to protect.

The system will be sized for maximum or peak flow rate based

on the specification of said equipment. A OneFlow

®

system

may also be installed to protect multiple pieces of equipment

from the ill-effects of hard water scale provided the aggregate

peak flow rate for each piece of equipment it is protecting has

been considered. The system shall be plumbed with a bypass

valve to allow isolation of filter housing to allow the bypass of

untreated water in the event that service or cartridge replace-

ment be necessary. Bypass is recommended but not required.

The installation area should be suitable in size for the housing

to be serviced without encumbrance and the system should be

installed per the Installation, Operation & Maintenance manual

as provided with each system.
The OneFlow

®

system must not require additional wastewater

to backwash, flush, or regenerate once put into service. The

system shall not require any chemical additives and shall not

require electricity for operation.

Note: Copper lines need to be passivated for a minimum

of 4 weeks before placing unit into service. Not for use on

closed loop systems.

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,
please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with-
out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

OFTWH-RES

*The wetted surface of this product contacted by consumable

water contains less than 0.25% of lead by weight.

For hot water applications where untreated feed water temperature
is 110°F - 150°F (43°C - 66°C), please consult ES-OneFlow-HotWater.

LEAD FREE

*