II. OPERATION

The key switch must be in the ON position (see Figure 1).

A.

Contrast

Adjustment

Press the up or down arrow when the Alamo Water logo is displayed to increase
or decrease the contrast of the display.


B.

Operation

Screen

When the Start/Stop button is pressed the inlet valve will open. After a 12 second
delay the pump will start. The system will operate according to the information
stored in memory. The product water conductivity is displayed in the large
numbers at the top center of the display. The temperature is displayed as degrees
Celsius in the top right corner of the display. The mode of operation is displayed
below the product water quality. Flush time information or pump run hours are
displayed on the bottom of the display.


C.

Configuration

Screen

Press the SELECT button to view the configuration screen. The software revision
level is displayed in the upper right corner of this screen. While the configuration
screen is displayed, the SELECT button moves the highlight cursor to the next
field. The up and down arrows change the value of the highlighted field. The
ACCEPT button saves all of the values and brings up the timer screen. The
RESET button discards all changes and brings up the timer screen. If no input is
detected for a continuous 30 seconds, the controller will discard all changes and
return to the operation screen. An asterisk appears next to a field whenever the
value of the field equals the value stored in memory. The configuration screen
contains the following field with their options:

MODE: (direct feed, tank feed, and standby)

LOW QUALITY: (2-200 micromhos) This is the set point for the diverter valve.
When the product water conductivity is equal to or greater than value selected, the
diverter valve output will be energized and the low quality LED will turn on.

AUTOSTART: (on/off) if "on" is selected, the system will automatically restart
after a power loss. If "off" is selected, the unit will not restart after a power loss.

LOWPRESSURE RETRY: (0-10) This is the number of times the system will
attempt to restart after a low pressure shutdown.

LOW PRESSURE DELAY: (15-90 seconds in 15 second increments) This is the
amount of time between attempts to restart after a low pressure shutdown.