Dimensions – Bosch W 125...T1 User Manual

Page 2

Advertising
background image

2

Maximum hydrostatic water pressure - 0.97 MPa (150 p.s.i.)
Maximum recommended working pressure - 0.69 MPa (100 p.s.i.)
Minimum working pressure - 0.01 1 MPa (2 p.s.i.) at 1.6 Litres/min. (0.5 U.S. Gal/min.) free discharge
Minimum recommended inlet water pressure for use with showers 40 p.s.i.g.

Dimensions in millimetres (inches)

* The high altitude ratings listed are Canadian Gas Association high altitude ratings and are only valid in Canada.
In the U.S., the National Fuel Gas Code, ANSI Z223.1/NFPA 54 recommends for high altitude installations above
2,000 feet, that the input rate be reduced 4% for each 1,000 feet above sea level.

DIMENSIONS

Figure 1

Standard

High

Standard

High

5,7

4,6

10,5

8,4

3,35

2,7

10,2

8,1

LPG

Altitude

Tap pressure inch

Manifold burner pressure inch

Altitude

Tap pressure inch

Manifold burner pressure inch

NG

Size, mm

Qt.

natural

standart

11.7 kW

1.25 diam.

6

propane

(0-2,000 ft.)

(40,000 Btu/hr)

0.76 diam.

6

natural

high *

10.5 kW

1.25 diam.

6

propane

(2,000-4,500 ft.)

(36,000 Btu/hr)

0.76 diam.

6

Main Burner Orifices

W 125 K…

W 125 K…

Model

Type of Gas

Altitude

Input

A

B

C

D

E

F

G

H

I

J

270

610

230

190

70

562

350

312

102

138

(10 5/8)

(25 3/8)

(9 1/8)

(7 1/2)

(2 3/4)

(22 1/8)

(13 3/4)

(12 1/4)

(4)

(5 3/8)

Advertising