I. Important Safety Information –

Read All

Filter Anatomy

!

CAUTION: Read and follow the information in this manual

to minimize the risk of electric shock or personal injury.
Important: If you are unsure about installing your Watts water

filter, contact a Watts representative or consult a professional

plumber.

A. READ Instructions Before Using

• After reading these instructions completely, obtain all the

materials and tools needed for installation.

NOTE: Failure to install the system correctly voids the warranty.
• Perform installation according to state, province and local

plumbing codes.

Use only lead-free solder and flux for sweat-solder

connections, as required by state, province and federal

codes.

• Handle all components of the system with care. Do not drop,

drag or turn components upside down.

• Be sure the floor under the water filter system is clean, level

and strong enough to support the unit.

• The system uses 24 volt-60Hz electrical power. Always use

the transformer supplied.

Plug transformer into an indoor 120 VAC, grounded outlet.

Properly ground the system to conform with all codes and

ordinances.

• Install the system in a protected area. Be sure electric outlet

and transformer do not come in contact with water. See

Installation Considerations, in the installation section of the

manual.

Do not attempt to treat water over 110°F (43°C) with the

system. Always connect the system to the main water

supply pipe before the water heater.

Do not expose the system to freezing temperatures. Wa-

ter freezing in the system causes equipment damage.

Do not install in direct sunlight. Ultraviolet rays from the

sun may cause damage.

• Minimum inlet water pressure is 30 psi. Maximum inlet water

pressure is 80 psi. Use a pressure reducing valve if neces-

sary.

!

CAUTION:

• Do not use with water that is microbiologically unsafe or of

unknown quality.

• Test the water periodically to verify that the system is per-

forming satisfactorily.

• Discard small parts remaining after the installation.

Figure 1

ITEM

DEscrIpTIon

1

Control Valve

2

Bypass Valve

3

Mineral Tank

4

Distributor Tube

5

Filter Media

6

Faceplate/Control

7

Garnet Underbedding

1

2

3

4

5

6

7

Advertising