Watts LF288A-DM User Manual

Series lf288a-dm, Lead free, For health hazard applications

Advertising
background image

Series LF288A-DM

(Deck/Equipment Mounted)

Hot or Cold Water Anti-Siphon

Vacuum Breakers

Sizes:

1

2

" (15mm)

Series LF288A-DM represents a complete line of vacuum

breakers designed to prevent backsiphonage of contaminated

water into a potable water supply.

They feature a lightweight, durable “disc float" suitable for

temperatures up to 180°F (82°C) which closes the atmospheric

vent to prevent spilling under all rates of flow. Therefore, they

are ideally recommended for low flow installations such as

laboratory equipment which use such a small amount of water.

They also contain a durable silicone disc which has high heat

and water hammer shock resistance and assures tight seating

with the lightest of seating contact. The LF288A-DM features

Lead Free* construction to comply with Lead Free* installation

requirements.

Full Size Orifice - Series LF288A-DM has a full-size orifice to

assure pipe size capacity. Water passages are streamlined to

provide high water flow with minimal pressure loss.

Features

• Lead Free* Brass Body

• Full size orifice for maximum flow

• Lightweight disc assembly prevents spilling under all

rates of flow

Models

LF288A-DM

with Lead Free* brass body

LF288AC-DM with Lead Free* brass body and polished

chrome finish

Specifications

For Anti-Siphon Vacuum Breakers
An atmospheric type anti-siphon vacuum breaker shall be in-

stalled where indicated on the plans to prevent the backsiphon-

age of contaminated water. Device shall include lightweight

disc float with silicone disc for tight seating. The device may be

installed 1" or higher above the highest point of downstream

piping. This device is not to be used under continuous pressure

or where there is a possibility that a backpressure condition

may develop. The (Deck/Equipment Mounted) Hot or Cold Wa-

ter Anti-Siphon Vacuum Breakers shall be constructed using

Lead Free* materials. Lead Free* (Deck/Equipment Mounted)

Hot or Cold Water Anti-Siphon Vacuum Breakers shall comply

with state codes and standards, where applicable, requiring

reduced lead content. The device shall meet the requirements

of ASSE Standard 1001, ANSI A112.1.1 and CSA B64 and

shall be a Watts Series 288A-DM.

For Health Hazard Applications

ES-LF288A-DM

1

/

2

" (15mm) LF288A-DM

Center Stem Guide

for accurate seating

Disc has high heat

and water hammer

shock resistance

Disc Float

durable and light-

weight, closes vent

with minimum flow

Full Size Orifice

assures pipe

size capacity

Since atmospheric type vacuum breakers are subject to normal main-

tenance and replacement, they should be located where emergency

water spillage will create no problem and where they can be accessible

for inspection or servicing.

This device shall not be subjected to continuous pressure for more

than twelve (12) hours per ASSE Std. 1001. For continuous pressure

application, specify Watts Series LF800 pressure type vacuum break-

ers. Vacuum breakers are not designed, tested or approved to protect

against backpressure backflow. For protection against backpressure

backflow, install Watts Series LF909 or Series LF009 reduced pressure

principle backflow preventers.

Job Name –––––––––––––––––––––––––––––––––––––––––––

Contractor ––––––––––––––––––––––––––––––––––––––––––––

Job Location –––––––––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Engineer –––––––––––––––––––––––––––––––––––––––––––––

Contractor’s P.O. No. ––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Representative ––––––––––––––––––––––––––––––––––––––––

LEAD FREE

*

*The wetted surface of this product contacted by consumable

water contains less than 0.25% of lead by weight.

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,
please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with-
out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

NOTICE