DENOISER SNR2000

We recommend the following control settings:

Controls

Settings

IN/OUT switch

IN

EXPANDER switch

IN

THRESHOLD control

-50 dBu

RELEASE control

2 seconds

RATIO control

3:1

FILTER switch

IN

SENSITIVITY switch

-30 dBu

AUTO switch

IN

Tab. 3.2: Initial settings of the DENOISER

3.2 Studio applications

3.2.1 Noise reduction during playback
For this standard application, the DENOISER is inserted after the master or multitrack machine, i.e. between

tape machine and mixer (or amplifier). A cassette recorder or similar machine may also be the signal source.

Fig. 3.1: Noise reduction during playback

1. Set up your equipment as usual, while bypassing your DENOISER.
2. Turn on the BEHRINGER DENOISER and adjust the controls as desired (if necessary, read chapter 1.3

“Control elements” once again).

3. Check your settings by making A/B comparisons using each channel’s IN/OUT switch.

3.2.2 Noise reduction during recording
The noise reduction effect may be increased by using the DENOISER not only during playback but also when

recording. For this purpose, insert the unit directly after the master output of the mixer into the recording path

of the master or multitrack machine. Set up the unit as described in the previous section “Noise reduction

during playback”.
In particularly difficult cases, we recommend using the DENOISER both during recording and playback.