Procedure for Extended Non-Use

(More than 2 months)

Turn off the water supply by turning the knob on the Adapt-A-

Valve™ clockwise until it stops and open the RO faucet to empty the

storage tank . (Save a few ounces of RO water) . Once the storage

tank is empty, remove the membrane and place it in a sealed plastic

bag with the RO water saved earlier and store in your refrigerator .
For restart, reinstall membrane (See Page 10 for membrane installa-

tion procedure) and follow Startup Instructions on Page 8 .

Membrane Replacement

This reverse osmosis system contains a replaceable component (the

RO membrane) which is critical to the efficiency of the system.
Replacement of this reverse osmosis membrane should be with one

of identical specifications as defined by Watts to assure the same

efficiency and contaminant reduction performance.
Membranes have a life expectancy between 2 and 5 years, de-

pending on the incoming water conditions and the amount the

RO system is used . This reverse osmosis membrane is critical for

effective reduction of total dissolved solids (TDS) . The product water

should be tested periodically to verify that the system is performing

satisfactorily .
Normally, a membrane would be replaced during a semiannual or

annual filter change . However, if at any time, you notice a reduction

in water production or an unpleasant taste in the reverse osmosis

water, it could be time to replace the membrane . Watts recommends

replacing the membrane when TDS reduction falls below 75% .
Note: A water sample may be sent to Watts for a free diagno-

sis of your membrane performance. To send a water sample,

use two (2) clean containers and fill ½ cup of tap water in one

container and ½ cup of reverse osmosis water in 2nd container.

Clearly label each sample. Send the samples to the address

listed on the cover of this manual attention “Water Samples”.

Watts will test the water and mail or call you with the results.
Step A – Turn off the incoming water sup-

ply to the RO by turning the knob

on the Adapt-A-Valve™ clockwise

until it stops .

Step B – Open the RO Faucet and allow

water to drain from the tank until

it is completely empty .

Removing the Membrane

Step A – Use a

5

8

" wrench to remove the

Green Tube fitting on the left

side of the horizontal mem-

brane housing (end with one

elbow) .

Step B – Remove the cap from the

Membrane Housing by turning

it counterclockwise to loosen .

Note: A double sided wrench may

be purchased from Watts to aid with

loosening the cap / filter housings.
Step C – Remove membrane hous-

ing from the holding clips .

Using a pair of pliers, grip the

PVC tube of the RO mem-

brane and pull firmly on the

membrane to remove from the

housing and discard .

Installing the Membrane

Step A – Lubricate the O-rings on the new membrane with a water

soluble lubricant such as KY Jelly ®. Insert the end with the

two black O-rings first into the housing .

Step B – Once membrane has been inserted into the housing, you

must take your thumbs and give a firm push to properly

seat the membrane . Replace membrane housing cap and

tighten .

Step C – After replacing membrane housing into clips, attach the

green tube to the elbow on cap using

5

8

" wrench .

Step D – Follow the Start Up Instructions on Page 8 .