Models replacement parts – Watts PWUVQ User Manual

Page 2

Advertising
background image

ES-WQ-PWUV 1225

© 2012 Watts

USA: Tel. (800) 224-1299 • www.watts.com

Canada: Tel. (888) 208-8927 • www.watts.ca

A Watts Water Technologies Company

Model No.

Flow Rate

PiPe Size

diMeNSioNS

electRical

ShiPPiNg weight

(gPM)

(l X w X h)

lbs.

kgs.

PWUV2110

2

1/2" MNPT

18" x 6" x 5-3/8"

110-130 v / 50-60 Hz

6

3

PWUV2220

2

1/2" MNPT

18" x 6" x 5-3/8"

200-250 v / 50-60 Hz

6

3

PWUV6110

6

3/4" MNPT

25-1/2" x 6" x 5-3/8"

110-130 v / 50-60 Hz

7

3

PWUV6220

6

3/4" MNPT

25-1/2" x 6" x 5-3/8"

200-250 v / 50-60 Hz

7

3

PWUV8110

8

3/4" MNPT

32" x 8-1/4" x 3-3/4"

110-130 v / 50-60 Hz

9

4

PWUV8220

8

3/4" MNPT

32" x 8-1/4" x 3-3/4"

200-250 v / 50-60 Hz

9

4

PWUV12110

12

1" MNPT

41-1/2" x 8-1/4" x 3-3/4"

110-130 v / 50-60 Hz

17

8

PWUV12220

12

1" MNPT

41-1/2" x 8-1/4" x 3-3/4"

200-250 v / 50-60 Hz

17

8

Flow Rate (gPM)

BUlB Model

BallaSt Model

QUaRtz SleeVe Model

2

PWUVBULB2

PWUVBAL2

PWUVQS2

6

PWUVBULB6

PWUVBAL6-12

PWUVQS6

8

PWUVBULB8

PWUVBAL6-12

PWUVQS8

12

PWUVBULB12

PWUVBAL6-12

PWUVQS12

Models

Replacement Parts

Specifications

Chamber materials

304SS

Max. water temperature

104°F (40°C)

Min. water temperature

36°F (2°C)

Max pressure

125psi

UV dose (end of life)

30 mj/cm2

Lamp life

9,000 hrs

Lamps per chamber

Single

Water Quality Guidelines

Total Iron

less than 0.3 mg/l

Hydrogen sulfide

less than 0.05 mg/l

Turbidity

less than 1.0 NTU

Manganese

less than 0.05 mg/l

Hardness

less than 7 grains

UV transmittance

greater than 90%

Note: Minimum water quality guidelines are recommended to ensure proper
operation and continuous disinfection.