3

TROUBLESHOOTING GUIDE

Possible Cause

Not plugged in securely.

Circuit breaker or fuse

open.

Drawer not closed.

Loose connection.

Defective key switch.

Defective motor.

Special Notes

Compactor should be on

separate 15 ampere

circuit (time-delay fuse

of circuit breaker recom-

mended.) Do not use an

extension cord with this

appliance.

See section on motor

replacement for test

procedure.

Condition

I. Will not run. Dead -

no sound. (Turn key

to start, if unit hums,

go to section III.

Correction

Insert plug securely into

outlet.

Check for condition

causing circuit breaker

or fuse to open. Correct

condition, then reset

circuit breaker or replace

fuse.

Push drawer to close.

Repair.

Replace.

Test motor - replace if

necessary.

III. Will not run - hums

when key held in

start position.

Defective upper limit

switch.

Loose connection.

Defective motor.

Plastic bag caught in

trunnion nut.

Replace.

Repair.

Test motor - replace if

necessary.

Remove plastic bag.

See section on motor

replacement for test

procedure.

See section on removing

bags from tunnion nut.

Do not use bags other

than the compactor trash

bag designed and sold

by Broan for use in this

compactor.

II. Runs continuously,

will not shut off.

Sprocket broken.

Chain derailed.

Gearbox broken.

Trunnion nut stripped.

Key switch incorrectly

connected.

Defective upper limit

switch.

Replace.

Reinstall chain.

Replace.

Replace.

Reconnect correctly.

Replace.

See note in section

covering chain derail-

ment.

Inspect trunnion nut for

any evidence of dam-

age. If nut displays signs

of thread destruction,

replace nut, clean drive

screw and regrease.

Advertising