Watts N9C User Manual

Series n9, For non-health hazard applications, Size

Advertising
background image

For Non-Health Hazard Applications

Series N9

Dual Check Vacuum Breakers

for In-Line Applications

Size

1

4

" and

3

8

" (8 and 10mm)

Series N9 Dual Check Vacuum Breakers for In-Line Applications
are used for continuous pressure, non-health hazard, applications.
These valves have NPT female inlet and outlet connection and
brass body construction.

Models

N9C – same as N9 except comes with chrome body

Pressure-Temperature

Temperature Range: 33°F – 180°F (5°C – 82°C)
Maximum Working Pressure: 150psi (10.3 bar)

Applications

Series N9 should be installed on each parlor sink where a hose is
attached. This series is for use on continuous pressure applications.

Open End,

only outlet on fixture

3

8

" Mixed

Water

Line

Drain

N9

Parlor Sinks

N9

Capacity

kPa psi

345 50
310 45

276 40

241 35

207 30

172 25

138 20

103 15

69 10

35 5

0 0 0 1 2 3 4 5 6 7

gpm

0

3.8

7.6

11

15

19

23

27 lpm

B

A

B

1

Dimensions — Weights

MODEL

SIZE (DN)

DIMENSIONS

WEIGHT

A

B

B

1

in.

mm

in.

mm

in.

mm

in.

mm

lbs.

kgs.

N9C

1

4

6

2

3

8

60

1

1

4

32

1

25

.38

.17

N9C

3

8

10

2

3

8

60

1

1

4

32

1

25

.38

.17

N9

1

4

6

2

3

8

60

1

1

4

32

1

25

.38

.17

N9

3

8

10

2

3

8

60

1

1

4

32

1

25

.38

.17

Standards

CSA B64.8

1

4

"

3

8

"

Pressure Drop

Flow

ES-N9 1322

© 2013 Watts

USA: Tel: (978) 688-1811 • Fax: (978) 794-1848 • www.watts.com
Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • www.watts.ca

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts
reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications
on Watts products previously or subsequently sold.

A Watts Water Technologies Company

Job Name –––––––––––––––––––––––––––––––––––––––––––– Contractor

––––––––––––––––––––––––––––––––––––––––––––

Job Location –––––––––––––––––––––––––––––––––––––––––– Approval

––––––––––––––––––––––––––––––––––––––––––––––

Engineer –––––––––––––––––––––––––––––––––––––––––––––

Contractor’s P.O. No. –––––––––––––––––––––––––––––––––––

Approval ––––––––––––––––––––––––––––––––––––––––––––– Representative

–––––––––––––––––––––––––––––––––––––––––

ES-N9