How to use the Quick-Connect fittings on the UF Module

To make a connection, the tube is simply pushed into the fitting .

Place a piece of tape

1

2

" from end of tube to indicate how far the

tube should be inserted . The unique patented Quick-Connect lock-

ing system holds the tube firmly in place without deforming it or

restricting flow .

Cut the tube square . It is essential that the outside diameter be free of score marks

and that burrs and sharp edges be removed before inserting into fitting .

Fitting grips before it seals . Ensure tube is pushed into the tube stop .

Push the tube into the fitting, to the tube stop . The collet (gripper) has stainless

steel teeth which hold the tube firmly in position while the O-ring provides a perma-

nent leak proof seal .

Pull on the tube to check that it is secure . It is a good practice to test the system

prior to leaving site and /or before use .

To disconnect, ensure the system is depressurized before removing the tube . Push

in collet squarely against face of fitting . With the collet held in this position, the tube

can be removed . The fitting can then be reused .