Ustang, Eries, Sizing – Watts M1115 User Manual

Page 3: Cavitation chart

Advertising
background image

12541 Gulf Freeway

Houston, Texas 77034

(Ph) 713.943.0688

(Fx) 713.944.9445

www.watts.com

M

ustang

s

eries

Sizing

CAVITATION ZONE

INLET PRESSURE - PSI

OUTLET PRESSURE - PSI

300

280

260

240

220

200

180

160

140

120

100

80

60

40

20

0

10 20

40

50

60

70

80

90

130 140

120

110

100

30

CAVITATION CHART

After selecting the valve size, locate inlet and outlet pressures on this chart. If the intersection point falls

in the shaded area, cavitation can occur. Operation of valves continually in the cavitation zone should be

avoided. Consult Watts ACV for alternatives.

Cavitation Chart

NOTE: The above chart is a suggested guide. Inlet pressure, outlet pressure, minumum, normal and maximum flow rates should

be considered for specific valve sizing. Contact Watts ACV for details.

Size (in)

1-1/4

1-1/2

2

2-1/2

3

4

6

8

10

12

14

16

Maximum Continuous

(GPM)

95

130

210

300

485

800

1850

3100

5000

7000

8400

11100

Maximum Intermittent

(GPM)

119

161

265

390

590

1000

2300

4000

6250

8725

10500 13300

Minimum Continuous

(GPM)

1

1

1

20

30

50

115

200

300

400

500

650

Valve Size (in)

1-1/4

1-1/2

2

2-1/2

3

4

6

8

10

12

14

16

fl.oz.

4

4

4

10

10

22

70

-

-

-

-

-

U.S. Gal

-

-

-

-

-

-

-

1-1/4

2-1/2

4

6-1/2

9-1/2

Valve Size (in)

1-1/4

1-1/2

2

2-1/2

3

4

6

8

10

12

14

16

Travel (in)

3/8

3/8

1/2

5/8

3/4

1

1-1/2

2

2-1/2

3

3-1/2

4

M115 (Globe)

M1115 (Angle)

Advertising