MODEL 2900s

3200 Timer Setting Procedure

How To Set Days On Which Water
Conditioner Is To Regenerate:
Rotate the skipper wheel until the number “1” is at the red pointer.
Set the days that regeneration is to occur by sliding tabs on the
skipper wheel outward to expose trip fingers. Each tab is one day.
Finger at red pointer is tonight. Moving clockwise from the red
pointer, extend or retract fingers to obtain the desired regeneration
schedule.

How To Set The Time Of Day:
Press and hold the red button in to disengage the drive gear.
Turn the large gear until the actual time of day is at the time of day
pointer.
Release the red button to again engage the drive gear.

How To Manually Regenerate Your Water
Conditioner At Any Time:
Turn the manual regeneration knob clockwise.
This slight movement of the manual regeneration knob engages the
program wheel and starts the regeneration program.
The black center knob will make one revolution in the following
approximately three hours and stop in the position shown in the
drawing.
Even though it takes three hours for this center knob to complete one
revolution, the regeneration cycle of your unit might be set only one
half of this time.
In any event, conditioned water may be drawn after rinse water
stops flowing from the water conditioner drain line.

How to Adjust Regeneration Time:
1. Disconnect the power source.
2. Locate the three screws behind the manual regeneration knob

by pushing the red button in and rotating the 24 hour dial until
each screw appears in the cut out portion of the manual
regeneration knob.

3. Loosen each screw slightly to release the pressure on the time

plate from the 24 hour gear.

4. Locate the regeneration time pointer on the inside of the 24

hour dial in the cut out.

5. Turn the time plate so the desired regeneration time aligns next

to the raised arrow.

6. Push the red button in and rotate the 24 hour dial. Tighten each

of the three screws.

7. Push the red button and locate the pointer one more time to

ensure the desired regeneration time is correct.

8. Reset the time of day and restore power to the unit.

SERVICE

POSITION

INDICATOR

24 HR. GEAR

MANUAL REGENERATION KNOB

RED TIME

SET BUTTON

SKIPPER WHEEL, 12 DAY

(SHOWS EVERY OTHER

DAY REGENERATION)

3200 ADJUSTABLE REGENERATION TIMER