Watts B911S User Manual

Series 911, Combination fill valve and backflow preventer, For residential and commercial applications

Advertising
background image

For Residential and Commercial Applications

ES-911

Job Name –––––––––––––––––––––––––––––––––––––––––––

Contractor ––––––––––––––––––––––––––––––––––––––––––––

Job Location –––––––––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Engineer –––––––––––––––––––––––––––––––––––––––––––––

Contractor’s P.O. No. –––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Representative ––––––––––––––––––––––––––––––––––––––––

911

MODEL

SIZE (DN)

DIMENSIONS

WEIGHT

A

B

in.

mm

in.

mm

in.

mm

lbs.

kgs.

911

1

2

15

8

1

2

216

5

1

4

133

4.2

1.9

911S

1

2

15

8

1

2

216

5

1

4

133

4.2

1.9

B911

1

2

15

8

1

2

216

5

1

4

133

4.2

1.9

B911S

1

2

15

8

1

2

216

5

1

4

133

4.2

1.9

Series 911

Combination Fill Valve and
Backflow Preventer

Size:

1

2

" (15mm)

Series 911 combination fill valve and backflow preventer consists of
a Model 9D backflow preventer and Model 1156F feed water pres-
sure regulator in one pre-assembled unit. This valve is designed for
use on boiler feed lines to provide make-up water to the boiler and
prevent backflow when supply pressure fails below system pressure.

Features

• Pre-assembled for ease of installation

• Easy service accessibility

• High capacity fill valve for quick system filling and purging

Models

911

– union NPT x NPT connections

911S

– union solder x NPT connections

B911

– all bronze body construction union

NPT x NPT connections

B911S – all bronze body construction union

solder x NPT connections

Specifications

A combination fill valve and backflow preventer shall be installed on
the boiler feed line to provide make-up water to the boiler. The valve
shall contain a Watts Regulator Model 9D backflow preventer and
Model 1156 feed water pressure regulator. The combination fill
valve and backflow preventer shall be a Watts Regulator Company
Series 911.

Pressure – Temperature

Maximum Temperature: 212°F (100°C)
Maximum Working Pressure: 100psi (6.9 bars)
Adjustment Range: 10-25psi (68.7 – 172.4 kPa) set at 15psi

(103.4 kPa)

Options

add suffix:

S –

1

2

" (15mm) union solder inlet x

1

2

" (15mm) threaded outlet

add prefix:

B – bronze body regulator

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,
please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials without
prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

USA: 815 Chestnut St., No. Andover, MA 01845-6098; www.wattsreg.com

Canada: 5435 North Service Rd., Burlington, ONT L7L 5H7; www.wattscda.com

ES-911 0329

©Watts Regulator Company, 2003

Printed in U.S.A.

Dimensions — Weights

A

B

Advertising
This manual is related to the following products: