Water supply, Minimum entry clearance, Shipping information – Blodgett DFG-200 User Manual

Page 3: Dimensions, Power supply, Gas supply

Advertising
background image

BLODGETT COMBI

www.blodgett.com

44 Lakeside Avenue, Burlington, VT 05401 • Phone: (802) 658-6600 • Fax: (802) 864-0183

BC-14G STACKED ON A DFG-200

SHORT FORM SPECIFICATIONS
Provide Blodgett model BC-14G gas synergy combination-oven/steamer stacked on a model DFG-200 full-sizeconvection oven.
BC-14G Combi - Unit shall have the ability to cook with pressureless steam, hot air, or combination of steam and hot air. Mechanical mode switch shall allow the operator to choose four
modes, steam, hot air, combi or cool down mode. Timer to be 120 minute motor driven. Temperature control to be solid state with rotary knob. Unit shall include two speed fan, steam on
demand feature, deliming indicator light and Vario Steam® feature. The interior shall have the capability of being hosed down for cleaning. Door gaskets shall be easily removable for replace-
ment and cleaning. Unit shall be open vented for waist air quenching. Steam generator shall be separate from the cooking compartment in order to provide the fastest possible steam recov-
ery. Steam generator shall flush automatically to cut down on mineral build up. A start-up inspection service will be performed by our factory authorized agent at no cost to the operator.
DFG-200 - Shall have (porcelainized/stainless) steel liner and shall accept five 18" x 26" standard full-size bake pans in left-to-right or front-to-back positions. Stainless steel front, top
and sides. Doors shall (be solid stainless steel/have dual pane thermal glass windows) with single porcelain handle and simultaneous operation. Unit shall be gas heated with electronic
spark ignition and shall cook by means of a dual-flow system combining direct and indirect heat and a gas shutoff switch on the front of the control panel. Air in baking chamber dis-
tributed by dual inlet blower wheel powered by a two-speed, 1/3 HP motor with thermal overload protection. Each chamber shall be fitted with two commercial lamps and five chrome-
plated removable racks. Control panel shall be recessed with Cook/Cool Down mode selector, solid state (manual/digital) infinite thermostat (200- 500° F), and 60 minute timer.
Provide options and accessories as indicated.

Printed in U.S.A.

NOTE: FOR COMMERCIAL USE ONLY

NOTE: The company reserves the right to make substitutions of
components without prior notice

APPROVAL/STAMP

P/N 39351 Rev C (1/07)

43-1/2”

(1105)

31-3/4”

(806)

180°

2” (151)

36-1/4” (921)

65”

(165)

41-1/8” (1045)

0” (0)

32” (813)

38-1/4” (972)

DIMENSIONS ARE IN INCHES (MM)

60-1/16”

(1526)

40-1/16”

(1018)

26-3/4”

(679)

10-1/2”

(267)

0” (0)

TOP RACK

BOTTOM RACK

WATER SUPPLY (

BC-14G only

):

Minimum Water Quality - not to exceed 30 parts per million of
dissolved solids. PH should be 7.0 or higher.
40(min)-50(max) PSI

122°F (50°C) avg. drain temperature

2" drain connection

3/4" hose cold water (Hot or filtered water
optional, order part #R9603)

MINIMUM ENTRY CLEARANCE:

BC-14G

DFG-200

Uncrated

36-1/4" (921mm)

32-1/16" (814mm)

Crated

42" (1066.8mm)

37-1/2" (953mm)

SHIPPING INFORMATION:

Approx. Weight:
BC-14G

650 lbs. (295 kg)

DFG-200

650 lbs. (295 kg)

Crate sizes (per section):
BC-14G

53" H x 45" W x 42" D (1346.2 x 1143 x 1066.8mm)

DFG-200

37-1/2" (952mm) x 43-1/2" (1105mm) x
52" (1321mm)

DIMENSIONS:

Product clearance

6" from combustible and non-combustible
construction. 12” on left side if not on casters.

Additional Height:
6" adjustable legs

6-7/8" - 8" (174.6-203.2mm)

POWER SUPPLY:

BC-14G:

120VAC 15 amp Nema 5-15 receptacle

DFG-200:

3-wire, 6 Amp, 115 VAC, 1 phase, 60 Hz. 1/3 H.P.,
2 speed motor, 1140 and 1725 RPM

2-wire, 3 Amp, 230VAC CE model, 1 phase, 50 Hz.
1/3 H.P., 1 speed motor, 1425 RPM

Both units:

6' (1.8m) electric cord set furnished.

Each unit requires a dedicated 15 amp. circuit.

GAS SUPPLY:

BC-14G

DFG-200

Connection:

3/4" NPT

3/4" NPT

Inlet Pressure:
Natural

7.0" W.C.

7.0" W.C. minimum
10.5" W.C. maximum

Propane

14.0" W.C.

11.05" W.C. minimum
13.0" W.C. maximum

Manifold Pressure:
Natural

N/A

3.5 W.C.

Propane

N/A

10.0 W.C.

Maximum Input:

115,000 BTU/hr

60,000 BTU/hr

Advertising
This manual is related to the following products: