Sizing and Placement

Rule 1 covers multiple fixture branch lines which do not

exceed 20 ft. (6m) in length.
Explanation - Fixture-unit sizing and selection table is used

to select the required PDI unit (water hammer arrestor).
Rule 2 covers multiple fixture branch lines which do exceed

20 ft. (6m) in length.
Explanation - Fixture-unit sizing and selection table is used

to select the required PDI unit (water hammer arrestor). The

sum of the fixture units rating of units X and Y shall be equal

to or greater than the demand of the branches.

X

Up to 20 ft. (6m)

Y

X

Over 20 ft. (6m)

Rule 1

Rule 2

Riser

Typical Branch Line

No. 15M2

Water Hammer Arrestor

As shown, it has been established that the preferred location

for the water hammer arrestor is at the end of the branch line

between the last two fixtures served.
The location of the water hammer arrestor shown above applies

to branch lines that do not exceed 20 ft. (6m) in length, from the

start of the horizontal branch line to the last fixture supply on

this branch line. When the branch line exceeds the 20 ft. (6m)

length, an additional water hammer arrestor should be used.

This practice is best defined by two rules which have been

established to cover the placement of water hammer arrestors.

Sizing and Selection Table

Fixture Units Sizing Information

Dimensions - Weight

Size (DN)

MODeL

ORDeR CODe

CROSS FiXTURe

UNiTS

ReF. PDi

STANDARD

in. mm

Threaded

1

2

" 15

15M2-A

0750140

1-11

A

3

4

" 20

15M2-B

0750141

12-32

B

1" 25

15M2-C

0750142

33-60

C

1" 25

15M2-D

0750143

61-113

D

1" 25

15M2-E

0750144

114-154

E

1" 25

15M2-F

0750145

155-330

F

Size (DN)

DiMeNSiONS

WeighT

A

B

in.

mm

in.

mm

(lbs)

(kgs)

Threaded

1

2

" 15M2-A

1

1

8

28.5

5

15

16

150.9

0.5

0.2

3

4

" 15M2-B

1

3

8

34.9

8

9

16

218.0

0.9

0.4

1" 15M2-C

1

5

8

41.3

8

13

16

223.5

1.3

0.6

1" 15M2-D

2

1

8

54.0

9

15

16

252.5

2.0

0.9

1" 15M2-E

2

1

8

54.0

12

11

16

322.5

2.3

1.1

1" 15M2-F

2

5

8

66.7

11

5

32

283.5

2.7

1.2

FiXTURe UNiTS

TYPe OF SUPPLY

PUBLiC

PRiVATe

FiXTURe

CONTROL

TOTAL C.W. h.W. TOTAL C.W. h.W.

Water Closet 1.66 PF

Flush Valve

8

8 –

5

5

Water Closet 1.66 PF

Flush Tank

5

5 –

2.5 2.5 –

Pedestal Urinal 1.06 PF

Flush Valve

4

4 –

Stall or Wall Urinal

Flush Valve 1.06 PF 4

4 –

Stall or Wall Urinal

Flush Tank 1.06 PF 2

2 –

Lavatory

Faucet

2 1

1

/

2

1

1

/

2

1

1

1

Bathtub

Faucet

4

2 3

2 1

1

/

2

1

1

/

2

Shower Head

Mixing Valve

4

2 3

2

1

2

Bathroom Group

Flush Valve Closet –

– –

8

8

3

Bathroom Group

Flush Tank Closet –

– –

6

6

3

Separate Shower

Mixing Valve

– –

2

1

2

Service Sink

Faucet

3

3 3

Laundry Tubs (1-3)

Faucet

– –

3

3

3

Combination Fixture

Faucet

– –

3

3

3

B

A

ES-15M2 1103

© 2011 Watts

USA: No. Andover, MA • Tel. (978) 688-1811 • Fax: (978) 794-1848 • www.watts.com

Canada: Burlington, ONT. • Tel. (905) 332-4090 • Fax: (905) 332-7068 • www.wattscanada.ca

A Watts Water Technologies Company