Watts FHB User Manual

Series fhb, Frost-proof automatic self-draining wall hydrants, For residential and commercial applications

Advertising
background image

For Residential and Commercial Applications

ES-FHB

Job Name –––––––––––––––––––––––––––––––––––––––––––

Contractor ––––––––––––––––––––––––––––––––––––––––––––

Job Location –––––––––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Engineer –––––––––––––––––––––––––––––––––––––––––––––

Contractor’s P.O. No. ––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Representative ––––––––––––––––––––––––––––––––––––––––

Series FHB

Frost-Proof Automatic Self-Draining

Wall Hydrants

Sizes:

1

2

" x

1

2

",

1

2

" PEX,

3

4

" x

1

⁄2",

3

4

" x

3

4

"

(15 x 15, 15, 20 x 15, 20 x 20mm)

Series FHB Frost-Proof Automatic Self-Draining Wall Hydrants

are designed to provide freeze protection of the external water

supply as well as backflow protection to the potable water supply.

FHB hydrants feature solid brass construction with nickel-plated

finish, 0.8mm thick copper tube, brass vacuum breaker, a heavy

metal handle and they can be repaired inline without removing the

sillcock from the waterline. These hydrants are designed to ASSE

Standard 1019 and are certified to CAN-B125-M89 and CAN/CSA

B64.2-M88.

Features

• Frost-proof design drains automatically
• Brass vacuum breaker prevents contamination of the potable

water supply from backsiphonage and backpressure

• FHB-1-PEX model features

1

2

" PEX inlet connection

• ASSE Standard 1019, IAPMO listed
• Metal handle
• 0.8mm copper tube thickness, thicker wall than competitors
• Size, length indication printed on cap for easy field service or repair

3

4

" (20mm) hose connection

Models

FHB-1 - For wall sizes: 4" – 14" (100 – 350mm),

1

2

" (15mm)

solder or

1

2

" (15mm) male IPS inlet

FHB-1-PEX - For wall sizes: 4" – 14" (100 – 350mm),

1

2

" (15mm) PEX inlet

FHB-2 - For wall sizes: 4" – 14" (100 – 350mm),

3

4

" (20mm) male

IPS or

1

2

" (15mm) female IPS inlet.

FHB-2

3

4

" - For wall sizes: 12" (300mm),

3

4

" (20mm) solder

or

3

4

" (20mm) male IPS

Standards — Approvals

ASSE Std. 1019, CSA certified to CAN-B125-M89 and
CAN/CSA B64.2-M88

Specifications

A frost-proof automatic self-draining wall hydrant shall be installed

where indicated in the plans. Hydrant to be manufactured with brass

body with nickel-plated finish, brass vacuum breaker mechanism,

metal handle, and 0.8mm copper tube wall thickness. Plastic han-

dles and/or plastic backflow mechanism is not acceptable. Hydrant

shall have either copper, IPS, or PEX inlet with 3⁄4" (20mm) hose

outlet. Hydrant shall be a Watts Regulator Company Series FHB.

Dimensions – Weights

model

size

dimeNsioNs

WeiGHT

A

B

in.

mm

in.

mm

in.

mm

lbs.

kgs.

inlet

1

2

" (15mm) solder or

1

2

" (15mm) male iPs

FHB-1

4

100

5

1

2

139.5 3

15

32

88.1

2.4

1.1

FHB-1

6

150

7

1

2

190.5 3

15

32

88.1

2.6

1.2

FHB-1

8

200

9

1

2

241.5 3

15

32

88.1

2.8

1.3

FHB-1

10

250

11

1

2

292.5 3

15

32

88.1

3.0

1.4

FHB-1

12

300

13

1

2

343.5 3

15

32

88.1

3.2

1.5

FHB-1

14

350

15

1

2

394.5 3

15

32

88.1

3.4

1.5

inlet

1

2

" (15mm) PeX

FHB-1-PEX

4

100

6

14

32

164

3

15

32

88.1

2.4

1.1

FHB-1-PEX

6

150

8

14

32

241

3

15

32

88.1

2.6

1.2

FHB-1-PEX

8

200

10

14

32

265

3

15

32

88.1

2.8

1.3

FHB-1-PEX

10

250

12

14

32

316

3

15

32

88.1

3.0

1.4

FHB-1-PEX

12

300

14

14

32

367

3

15

32

88.1

3.2

1.5

FHB-1-PEX

14

350

16

14

32

418

3

15

32

88.1

3.4

1.6

inlet

3

4

" (20mm) male iPs or

1

2

" (15mm) female iPs

FHB-2

4

100

5

1

2

139.5 3

15

32

88.1

2.3

1.0

FHB-2

6

150

7

1

2

190.5 3

15

32

88.1

2.4

1.1

FHB-2

8

200

9

1

2

241.5 3

15

32

88.1

2.5

1.1

FHB-2

10

250

11

1

2

292.5 3

15

32

88.1

2.6

1.2

FHB-2

12

300

13

1

2

343.5 3

15

32

88.1

2.7

1.2

FHB-2

14

350

15

1

2

394.5 3

15

32

88.1

2.9

1.3

inlet

3

4

" (20mm) solder or

3

4

" (20mm) male iPs

FHB-2

3

4

"

12

300

13

1

2

343.5 3

15

32

88.1

2.7

1.2

ES-FHB 1139

© 2011 Watts

USA: No. Andover, MA • Tel: (978) 688-1811 • Fax: (978) 794-1848 • www.watts.com
Canada: Burlington, ON • Tel: (905) 332-4090 • Fax: (905) 332-7068 • www.wattscanada.ca

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts
reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications
on Watts products previously or subsequently sold.

A Watts Water Technologies Company