Troubleshooting – Broilmaster P3FBLW-2 User Manual

Page 22

Advertising
background image

Page 22

B101362-2-0610

Although the manufacturer has attempted to ensure that your grill will operate properly and satisfactorily, some-

times problems do arise. The following troubleshooting guide lists several possible problems and their probable

cause and solution.

Problem

Cause

Solution

Burner will not light.

Gas injector not inserted in venturi

tube.

Realign/engage gas injector with the

venturi tube.

Clogged gas injector.

Remove gas injector from gas control

assembly and clean.

Obstruction in gas line.

For propane models, ensure gas valve

on cylinder is OFF. Remove flexible

hose and blow out any debris.

Spider webs in venturi tubes.

Clean venturi tubes. See Maintenance

Section.

Misalignment of collector box and

burner.

Position electrode properly. Clean col-

lector box.

Out of gas

Refill LP gas cylinder. If natural model,

turn on gas at source.

Dead battery.

Replace with AA Alkaline battery.

Inadequate grill tempera-

ture.

Poor combustion.

Adjust air shutter.

Misalignment of venturi tube and gas

injector.

Realign/engage gas injector with the

venturi tube.

Inadequate gas pressure.

Contact gas supplier for assistance.

Incorrect orifice/valve setting.

Refer to gas conversion instructions in

this manual.

Flames blow out.

Cold grill.

Preheat grill at least 5 minutes on HI

with the grill lid closed.

Misalignment of burner tube and gas

injector.

Realign/engage gas injector with the

burner tube.

Poor combustion.

Adjust air shutter.

Extreme wind.

Turn or shield grill.

Yellow flames.

Air shutter improperly set.

Open air shutter

Spider webs in venturi tubes.

Clean venturi tubes. See Maintenance

Section.

Seasoning salts on burner.

Clean by washing burner with mild

detergent.

Oil film on burner.

Allow burner to operate on HI for 10-

15 minutes.

TROUBLESHOOTING

Advertising