Please read all of these instructions carefully before
installing your new faucet.

Helpful tools to install this faucet

• a basin wrench

• plumbers putty

• Teflon tape

• flashlight

• crescent

• faucet supply

wrenches (2)

tubes

Important Points

• When installing your new faucet, hand tighten the

connector nuts. Use one wrench to anchor the fitting
and the second wrench to tighten the nut one addi-
tional turn. Connections that are too tight will reduce
the integrity of the system.

• Wrap all the threaded connections (except

aerator thread in faucet body) with Teflon tape.
Always wrap in a clockwise direction.

• Prior to beginning installation, turn off the cold and

hot water lines, open the old faucet, and flush
toilet to release build-up pressure. Then cut both
water supply pipes approximately 15" below the bot-
tom of the old faucet, taking care that the pipes
remain circular. Use fine-grit sandpaper to remove
any burrs or rough edges from the cut ends.

Single Handle Tub & Shower Faucet

Double Handle Tub & Shower Faucet

1

. Shut off main water supply.

Install rigid casting to
1/

2" water lines. Tailpieces on

water lines are threaded for
1/

2" threaded pipe and will

accept 1/2" sweat copper.

2

. For tub installation only, plug

top outlet. For shower installa-
tion only, plug bottom outlet.

3

. For tub and shower

combined installation, connect
bottom outlet to spout. Use new
piece of 1/2" threaded pipe and
proper fittings. Connect top out-
let to shower arm with proper
fittings.

4

. Turn on water. Slip handles

on loosely. Check for leaks.
Flush hot and cold lines for one
minute each. Caution:
Do not turn water off and
on repeatedly during initial
flushing period.

5

. Slide escutheons onto valves

and back against
finished wall. Screw on
handles and insert hot
and cold buttons.

1

1

2

3

4

2

3

4

5

1

. Shut off main water

supply. Make opening in back
wall large enough to work.

2

. Connect water supply lines.

(Looking at faucet
from tub, right is cold
and left is hot.)

3

. Connect tub spout using

1/

2" pipe and 90º elbow.

4

. Remove handle and attach

round escutcheon. Replace
handle. Turn screw on handle
through valve stem prior to
placing cap on handle. Flush
both hot and cold water lines
for one minute each.

IS-E800

IS-E800 0845

EDP# 1915397

© Watts, 2008

USA: 815 Chestnut St., No. Andover, MA 01845-6098; www.watts.com

Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca

B r a s s & T u b u l a r P r o d u c t s

Limited Warranty: Watts Regulator Co. (the “Company”) warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date
of original shipment. In the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge.
THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT. THE COMPANY MAKES NO OTHER WAR-
RANTIES, EXPRESS OR IMPLIED. THE COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of warranty, and the Company shall not be responsible for any incidental, spe-
cial or consequential damages, including without limitation, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs result-
ing from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical, or any other circumstances over which the Company has
no control. This warranty shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or alteration of the product.
Some States do not allow limitations on how long an implied warranty lasts, and some States do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above
limitations may not apply to you. This Limited Warranty gives you specific legal rights, and you may have other rights that vary from State to State. You should consult applicable state laws
to determine your rights. SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL SHIPMENT.