Master Programming Mode SXT

(continued)

14. Current Day (Display Code CD)

Press the Extra Cycle button . Use this display to set the current day

on systems that have been configured as Day of Week controls .

This setting is identified by "CD" in the upper left-hand corner of the

screen . Use the Up and Down buttons to select from Day 1 through

Day 7 .

Figure 25

15. Flow Meter Type (Display Code FM)

Press the Extra Cycle button . Use this display to set the type of flow

meter connected to the control . This option setting is identified by

"FM" in the upper left-hand corner of the screen . Use the Up and

Down buttons to select one of the 8 available settings .

Abbreviation

Description

P0.7

3/4" Paddle Wheel Meter

t0.7

3/4" Turbine Meter

P1.0

1" Paddle Wheel Meter

t1.0

1" Turbine Meter

P1.5

1.5" Paddle Wheel Meter

t1.5

1.5" Turbine Meter

P2.0

2" Paddle Wheel Meter

Gen

Generic or Other non-Fleck Meter

Figure 26

16. Meter Pulse Setting (Display Code K)

Press the Extra Cycle button . Use this display to specify the meter

pulse setting for a non-standard flow meter . This option setting is

identified by "K" in the upper left-hand corner of the screen . Use the

Up and Down buttons to enter the meter constant in pulses per unit

volume .

Figure 27

17. End of Master Programming Mode

Press the Extra Cycle button to save all settings and exit Master

Programming Mode .

W110 LXT Downflow Softeners and SXT Filters