ES-100DT

Model: 100DT - A60 - 12

Model: 100DT - A60

Model: 100DT - 72

Model: 100DT

MODEL

CONNECTION

DROP LENGTH

RUN

WEIGHTs

SIZE

A

B

in.

mm

in.

mm

in.

mm

lbs.

kgs.

100DT

3⁄4"

20

48"

1200

0.19 0.08

100DT-72

3⁄4"

20

72"

1800

0.20 0.09

100DT-A60

3⁄4"

20

60"

1524

8"

200

2.00 0.91

100DT-A60-12 3⁄4"

20

60"

1524

12"

300

2.00 0.91

6" (150mm) 

Air Gap*

A

6" (150mm) 

Air Gap*

A

B

Top Mount T&P Valve

*   Drain tube must be trimmed to 6" (150mm) above drain so that any relief 

discharge will be visible.

side Mount T&P Valve

Series 100DT

Drain Tubes

Size:

3

4

" (20mm)

Series 100DT Drain Tubes are used to easily provide a safe

discharge line from residential water heater temperature and

pressure relief valves. No special tools, fittings or sealants are

required to install these drain tubes, they are simply hand-

tightened to the T&P valve discharge.
Series 100DT Drain Tubes can be used on gas, electric or oil

fired water heaters to safely drain water discharged from the

heater’s temperature & pressure relief valve.

Features

• Models available for both side and top mounted T&P

relief valves

• No special tools required to install, simply hand-tightened
• Can be used on gas, electric or oil fired water heaters
• UPC and IAPMO listed, ASME A112.4.1 approved
• Meets Department of Housing and Urban Development

requirements

Pressure – Temperature

Maximum Operating Temperature: 250°F (121°C)
Maximum Working Pressure: 15psi (103.35 kPa)

Dimensions — Weights

ES-100DT 0404

© 2010 Watts

USA: No. Andover, MA • Tel. (978) 688-1811 • Fax: (978) 794-1848 • www.watts.com
Canada: Burlington, ONT. • Tel. (905) 332-4090 • Fax: (905) 332-7068 • www.wattscanada.ca

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts
reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications
on Watts products previously or subsequently sold.

A Watts Water Technologies Company

Job Name –––––––––––––––––––––––––––––––––––––––––––

Contractor ––––––––––––––––––––––––––––––––––––––––––––

Job Location –––––––––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Engineer –––––––––––––––––––––––––––––––––––––––––––––

Contractor’s P.O. No. ––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Representative ––––––––––––––––––––––––––––––––––––––––

Advertising
This manual is related to the following products: