II. INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR OIL INLET VALVE:

Connect the oil supply line to the oil inlet on the oil level controller. The minimum recommended supply line is ¾” I.D. The
supply line must be clean and it is recommended that it be flushed with solvent before installation.

Connect the oil supply line to the oil supply tank. If there is no existing valve at the tank or the existing supply outlet, a shut-off
valve should be placed in the line to prevent oil loss when cleaning the inlet screen or filter.

For high pressure models HP-A, pressure range must be between 5 psi and 34 psi. For high pressure units HP-B, pressure
range must be between 35 psi and 70 psi.

The oil inlet valve is adjusted to maintain the oil level at the center of the sight glass. Low or high levels are often caused by
two problems:
1. Excessive oil inlet pressure, which will cause the unit to overfill.
2. Improper equalizing lines between the crankcase and the controller will also result in improper levels.

Note: Low pressure models require a minimum of 2’ of head pressure and a maximum of 15’ of oil inlet head pressure.

III. INSTALLATION INSTRUCTIONS FOR UNITS WITH ADAPTERS:

OIL LEVEL CONTROLLERS WITH

–9

(Universal adapter),

-

10

(Slotted universal adapter),

-12

(Pole mounted adapter) AND –

FS OPTIONS

Set the controller so that the centerline of the sight window corresponds to the desired oil level in the crankcase.

Mount the controller close to the crankcase and connect the hose from the ¾” outlet located on the controller to the crankcase.
NOTE: The outlet port on the oil level controller must be located below the oil level in the crankcase.

An equalizing line must be used between the controller and crankcase in order to equalize the pressure. The tubing must be a
minimum of 1/2” I.D. and must be kept under 2 feet. DO NOT loop this line. It must be trap free and self draining, with a
downward pitch flow by gravity.





























OIL LEVEL CONTROLLER WITH

–11

AND

–11-FS

OPTION (for Mechanical Lubricators): See Figure 3




Drill holes in the lubricator housing as shown, and mount

the controller with the inlet located on the top side using the
seal washers and mounting bolts provided.

Place the seal washers between the controller and the

lubricator housing.

Figure 3