Klimaire KSIN024-H215 Installation User Manual

Ksin room air conditioner, Installation manual, Select the best location

Advertising
background image

1. Determine hole positions according to left and right
side of the installation plate. The hole center is obtained
by measuring the distance as shown in the diagram above.
2. Dirll the piping plate hole with ¦65mm hole-core drill.
3. Drill the piping hole at either the right or the left and the
hole should be slightly slanted to the outdoor side.
4. Always take steps to protect the pipe when drilling metal
grid,metal plate or the like.

DRILL A HOLE IN THE WALL

INSTALLATION PLATE MOUNTING

2

1

I

N
D
O
O
R

U
N

I

T

Except the above parts provided,the other parts needed during installation you must
purchase.

ACCESSORIES

NOTE:

SELECT THE BEST LOCATION

Please read these safety precautions carefully before installation
Be sure to follow all the precautions below, they are all important for ensuring safety.

This symbol indicates the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage to property.

1) This equipment must be grounded and installed with ground leakage current breaker. It may cause

electrical shock if grounding is not perfect.

2) Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and
accumulates at surrounding of the unit, it may cause fire.
3) Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water
may enter the room and damage the furniture.

1) Install according to this installation instructions strictly. If installation is defective, it will cause water

leakage, electrical shock,or fire.

2) Use the included accessories parts and specified parts for installation. otherwise, it will cause the set

to fall, water leakage, electrical shock fire.

3) Install at a strong and firm location which is able to withstand the set s weight. If the strength is not

enough or installation is not properly done, the set will drop and cause injury.

4) For electrical work, follow the local national wiring standard, regulation and this installation instructions.

An independent circuit and single outlet must be used. If electrical circuit capacity is not enough or

defect found in electrical work, it will cause electrical shock fire.

5) Use the specified cable and connect tightly and clamp the cable so that no external force will be acted

on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection.

6) Wiring routing must be properly arranged so that control board cover is fixed properly. If control board

cover is not fixed perfectly, it will overheat at connection point of terminal, fire or electrical shock.

7) When carrying out piping connection, take care not to let air substances other than the specified

refrigerant go into refrigeration cycle. Otherwise, it will cause lower capacity, abnormal high pressure

in the refrigeration cycle, explosion and injury.

8) Do not modify the length of the power supply cord or use of extension cord, and do not share the

single outlet with other electrical appliances. Otherwise, it will cause fire or electrical shock.

SAFETY PRECAUTIONS

CAUTION

WARNING

CAUTION

WARNING

Please read this installation manual carefully before operating the unit to ensure correct installation.
If the power cord is damaged, replacement work shall be performed by authorised personnel only.
Installation must be performed in accordance with the requirement of NEC and CEC by authorized
personnel only.
Contact an authorized service technician for repair, maintenance and installation of this unit.
This appliance is not intended for use by persons(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by persons responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
All the pictures in the instructions are for explanation purposes only. The actual shape should prevail.
The design and specifications are subject to change without prior notice for product improvement.
Consult with the sales agency or manufacturer for details.

There should not be any heat source or stream
near the unit.
There should not be any obstacles blocking the
air circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into
consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the
wall,ceiling,fence or other obstacles.
There should not be any direct sunlight. If unavoidable,
sunlight prevention should be taken into consideration.

Indoor unit

Outdoor unit

If an awning is built over the unit to prevent
direct sunsight or rain,be careful that heat
radiation from the condenser is not obstructed.
There should not be any animal or plant which
could be affected by hot air discharged.
Keep the spaces indicated by arrow from wall
ceiling, fence or other obstacles.
Do not place any obstacles which may cause
a short circuit of the discharged air.

Anchor the outdoor unit with a bolt and nut ¦10 or
¦8 tightly and horizontally on a concrete or rigid mount.

Settlement of outdoor unit

NOTE: The outdoor unit you purchase may be like one
of the following. Install the outdoor unit according to the
dimension as indicated in the table below:

A

W

B

D

Air inlet

Air outlet

Air inlet

INSTALLATION PRECAUTIONS

CONNECT THE CABLE TO THE INDOOR UNIT

3

,

Terminal block of indoor unit

Connect the cable to the indoor unit

Before performing any electrical work, turn off the main power to the system.
1. The inside and outside connecting cable can be connected without removing the front grille.
2. Lift the indoor unit panel up, remove the electrical box cover by loosening the screw.
3. Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor s
respectively.
4. Wrap those cables not connected with terminals with insulation tapes, so that they will not touch
any electrical components. Secure the cable onto the control board with the cord clamp.

NOTE:

Electrical box
cover

Front Panel

To outdoor unit

Cord clamp

1

2

3
4

5

7
8
9
10

6

Installation Plate

Clip Anchor

Self-tapping Screw A ST3.9x25

Seal(For cooling & heating models only)
Drain Joint(For cooling & heating models onlyŁ

Connecting
pipe
Assembly

Liquid side

Gas side

Remote controller

Air freshening filter(installed on Air filter)

Self-tapping Screw B ST2.9x10

¦6.35
¦9.52

¦9.52

¦12.7

¦ 16

Parts you must purchase. The pipe
size differ from appliance to appliance.
Consult the technician for the proper
size.

1
5-8(depending on models)

5-8(depending on models)

1

1

1
2

1

1

Remote controller holder

Number Name of Accessories

Qty

optional
parts

4

CONNECTIVE PIPE AND DRAINAGE INSTALLATION

1. Run the drain hose sloping downward.
Do not install the drain hose as illustrated
in wrong figures.
2. When connecting extension drain hose,
insulate the connecting part of extension
drain hose with a shield pipe, do not let
the drain hose slack.

Drainage

Right

Wrong

L1 L2 S

Outdoor unit dimension
mm(WxHxD)

A(mm)

B(mm)

530

523

290

340

560

335

Mounting dimensions

760x590x285

820x590x330

845x700x320

202000192527 CS197I2-11D1(H) 20121210

The cable size and the current of the fuse
or switch are determined by the maximum
current indicated on the nameplate which
located on the side panel of the unit.
Please refer to the nameplate before
selecting the cable, fuse and switch.

NOTE:

Suggest Minimum Wire Size
(AWG:American Wire Gage):

Appliance Amps

AWG Wire Size

10

13

18

25

18

16

14

12

30

10

Electric safety regulations for the initial Installation
1. If there is serious safety problem about the power supply, the technicians should refuse to install
the air conditioner and explain to the client until the problem is solved.
2. Power voltage should be in the range of 90%~110%of rated voltage.
3. The surge protector and main power switch with a 1.5 times capacity of Max. Current of the
unit should be installed in power circuit.
4. Ensure the air conditioner is grounded well.
5. According to the attached Electrical Connection Diagram located on the panel of the outdoor unit
to connect the wire.
6. All wiring must comply with local and national electrical codes and be installed by qualified and
skilled electricians.
7. An all-pole disconnection device which has at least 3mm separation distance in all pole and a residual
current device(RCD) with the rating of not exceeding 30mA shall be incorporated in the fixed wiring
according to the national rule.
8. An individual branch circuit and single receptacle used only for this air conditioner must be
available. See the following table for suggested wire sizes and fuse specifications:

Electrical wor k

Right rear side

refrigerant pipe

hole ¦65

Right rear side

refrigerant pipe

hole ¦65

Left rear side

refrigerant

pipe hole ¦65

Left rear side

refrigerant

pipe hole ¦65

150mm or more to ceiling

150mm or more to ceiling

Installation plate

Installation plate

Indoor unit outline

Indoor unit outline

120mm or

more to wall

120mm or

more to wall

120mm or

more to wall

120mm or

more to wall

Correct orientation
of Installation Plate

Model A

Model B

1030

1030

21.5

21.5

293

293

163

163

315

315

45

45

1. Fit the installation plate horizontally
on structural parts of the wall with
spaces around the installation plate.
2. If the wall is made of brick, concrete
or the like, drill five or eight 5mm
diameter holes in the wall.Insert Clip
anchor for appropriate mounting screws.
3. Fit the installation plate on the wall
with five or eight type A screws.

Mount the Installation Plate and drill
holes in the wall according to the
wall structure and corresponding
mounting points on the installation
plate. The installation plate provided
with the machine differ from appliance
to appliance.
(Dimensions are in mm unless
otherwise stated)

NOTE:

NOTE:

Installation Plate Mounting

The mounting wall is strong and solid
enough to prevent it from the vibration.

"

"

"

"

INSTALLATION MANUAL

KSIN ROOM AIR CONDITIONER

(Split Wall-Mounted Type)