Instructions for use – Opticron Universal Digital Camera Adapter User Manual

Page 2

Advertising
background image

The Universal Digital Camera Adapter is designed to allow you to take high magnification
photographs using Opticron telescopes and eyepieces in conjunction with most digital compact
cameras and some digital camcorders using eyepiece projection.

Many digital compact cameras do not have screw threads on the lens assemblies to allow for direct
coupling, so the UDCA is designed as a three-way adjustable balance plate that fixes directly to the
telescope eyepiece. The camera is fixed onto the UDCA and can be adjusted in three planes to
enable correct positioning with respect to the eyepiece.

Connection criteria
Maximum camera size:
distance from front of lens to centre of
tripod adapter socket no greater than 140mm. Distance from
centre of lens to base of camera no greater than 150mm.
Eyepiece: eyepiece diameter must be less than or equal to 56mm
and have a fixed/non rotating tube length of 15mm or more.

Instructions for use

Before connecting the adapter, set up your telescope and
eyepiece on a tripod as you would for viewing - focusing on an
object in the normal way until the image being viewed comes
into sharp focus.

Choosing an eyepiece
As a general rule, the following eyepieces provide the best overall
images with a wide range of different compact digital cameras. To
help they have been graded according to particular requirement.
1. Overall image quality: HDF 40810 or HR 40812
2. Flexibility across the widest range of different magnifications:

HDF 40862 zoom

3. Taking pictures at lower magnifications: 40929 DTL

Fixing the jaw clamp assembly onto the eyepiece [Fig. 1]
• Unscrew jaw clamp assembly to a distance greater than the

diameter of the eyepiece.
Place the jaw over the eyepiece and tighten using knob [A].

• Remove stop plate [B].

Fixing the balance plate assembly [Fig. 2]
• Using one of the three available holes, slide the balance plate

Assembly into the vertical pole with the grooved channel
facing up.
(The hole nearest the tightening screw [C] is recommended for
straight-through viewing telescopes.)

• Tighten the balance plate assembly using knob [C] in a

convenient position for fixing the camera.

• Re-attach stop plate [B].

Height adjusting post [D] [Fig. 3]
This screws onto 1/4inch thread equipment and raises the height
of small cameras enough to achieve vertical alignment with the
eyepiece. Recommended for use with cameras where the distance
from the base of the camera to the centre of the lens is less
than: 28mm - HR eyepieces 32mm - HR2 & HDF eyepieces.

Fixing the camera onto the balance plate assembly [Fig. 3]
• Screw the camera / camera + height adjustment post onto the balance plate via the sliding 1/4

inch thread.

• Tighten, leaving just enough play to allow you to slide the camera along the channel later on.

Aligning the camera to the eyepiece [Fig. 3]
To take photographs the camera and eyepiece need to be aligned in three planes: horizontal [X],
vertical [Y] and left to right [Z]. Optimum alignment position will be different for each camera and
eyepiece combination used. To locate the optimum position, the camera and balance plate
assembly must be moved in three planes and can take a little practice.

Important
Before you begin aligning the camera turn it on making sure the lens is fully extended

1

and the LCD

monitor is on. Doing this will help you make the alignment by viewing the LCD monitor and avoid
extending the lens into the eyepiece which may cause damage to both the camera and the eyepiece
lens.

1

The ability to obtain full frame images will be dependant on the objective lens diameter of the

telescope, the eyepiece being used and the diameter of the camera lens. Some camera lenses will
extend or retract when the optical zoom is increased. Make sure the lens is fully extended even if
this means the zoom function is at its lowest value. The zoom function can then be adjusted safely
after the camera is aligned correctly.

• To correctly position the camera move it in three dimensions as illustrated.
• As you move the camera into position the LCD monitor will begin to show a single rounded

picture of the image you originally set your scope and eyepiece to. Once this single rounded
picture is obtained you can adjust the zoom function to eliminate any vignetting and make any
fine focus adjustments using the focus on the telescope.

Optional accessory vertical lock ring
The vertical lock ring permits you to ‘fix’ the position of the balance plate assembly at any point
along the tube of the jaw clamp assembly. This in turn allows you to loosen the tightening screw
[C] and swing the camera + balance plate away from the eyepiece in order to view with the naked
eye. You can then swing the camera back into position ready for filming or taking photographs.

How to use
1. Fix the camera into position as per Instructions for use.
2. Remove stop plate [B] from jaw clamp assembly and slide the vertical lock ring into position at

point of contact with the underside of balance plate assembly and tighten.

3. Re-attach stop plate [B].

Important
When using the UDCA + vertical lock ring with 45 degree angled telescopes, make sure the camera
is fixed firmly to the balance plate assembly before ‘swinging.’

Tips for taking pictures
• Focusing for different distances is performed by the focus wheel or knob on the telescope
• Remember to set the flash function to OFF
• You may find setting the camera to macro mode will improve the final image
• If the camera has a remote control you may find this useful in reducing system shake

[Fig. 2] Fixing the balance
plate assembly

C

[Fig. 3] Fixing and aligning
the camera

D

Y

Z

X

[Fig. 1] Jaw clamp assembly

A

B

Advertising